Review Date Reviewer's Name Type of Review Description Status Comments
03/29/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
03/29/2023 Commercial Building REQUIRES RESUBMIT Provide a written response to all review comments.

1) Provide a narrative of the proposed use of the outdoor space.
2) Provide an Occupant Load (2018 IBC 1004.1) and Egress Plan for the existing building. 2018 IBC 1006.
3) Demonstrate means of egress continuity compliance. 2018 IBC 1003.6
4)Demonstrate accessible route within a site compliance. 2018 IBC 1104.1
02/13/2023 Fire New Construction REQUIRES RESUBMIT -Include OL for building to determine door swing.
-Doors/gates shall swing in the direction of egress travel if OL served is 50 or more. IFC 1010.1.2.1, 1010.2
03/07/2023 Site Engineering REQUIRES RESUBMIT See Zoning Comment
03/03/2023 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
TC-COM-0223-00598
8060 E 22nd St. – (1st Review)
Food Service - Outdoor Seating Area.

TRANSMITTAL: March 3, 2023
This site is located in C-2 zone (UDC 4.7.21), Food Service is a allowed use in the zone (UDC Table 4.8-4) subject to Use Specific Standards 4.9.4.M.1 and 4.9.13.P.

1. It appears that an outdoor seating area is proposed. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan.

2. It appears that the proposed rail is blocking a required sidewalk area. Clearly demonstrate on the development package that a minimum 4’-0” sidewalk is maintained, TSM Sections 7-01.4.1.C, 7-01.4.2 & 7-01.4.3.A.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
02/09/2023 PDSD Application Completeness REVIEW COMPLETED