Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.3
Permit Number - TC-COM-0223-00582
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/18/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
08/18/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 8/18/2023 11:20:15 AM See the building review comments. Building(B) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 8/18/2023 11:16:04 AM 1) Sheet A1.0 (Elevations) and M2.0 (Mechanical Drawings): The elevation views do not show the 30" servicing platform for the HVAC equipment as detailed in 2018 IMC section 306.5.1. The section requires a minimum 30" x 30" platform with guards for servicing equipment located on roofs with a slope of 3:12 or greater and where the roof edge is greater than 30" above the grade. 2) Sheet A1.0 (Elevations) and M2.0 (Mechanical Drawings): Sheets S1.0 and M1.0 show the HVAC equipment located straddling the ridge and an exterior duct penetrates the roof at a separate location. Sheets A1.0 and M2.0 detail #3 do not show this layout. Please coordinate and revise the plans. (2018 IBC section 107) Mechanical(M) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 8/18/2023 11:18:24 AM See the building review comments. Electrical(E) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 8/18/2023 11:16:54 AM See the building review comments. No electrical revisions are needed at this time. Plumbing(P) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 8/18/2023 11:19:50 AM See the building review comments. No plumbing revisions are needed at this time. |
||
08/04/2023 | Historic | REQUIRES RESUBMIT | Property is a non-contributing resource within the El Presidio Historic Preservation Zone. Please resubmit the required documents noted in the Historic & Special District informational handout (https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/submission-documents/special_districts_application_instructions_7.18.23.pdf). Revised plans should be resubmitted under the Historic sub record. | ||
07/11/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-COM-0123-00582 329 W Franklin St. – HO-3 Convert Garage to Commercial Kitchen (3rd Review) TRANSMITTAL: July 11, 2023 COMMENT: Resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in HO-3 zone (UDC 4.7.15), Medical Service Outpatient is an allowed use in the zone (UDC Table 4.8-3), subject to Use Specific Standard 4.9.13.K. 1. Zoning has reviewed the building plans for compliance with Development Package (DP) TD-DEV-0423-00218 and although the appear to match until the DP is approved by all review agencies Zoning cannot approve the building plans. COMMENTS: the following comments are relative to an application for Historic Review (UDC 5.8.8). 2. As exterior work is proposed Historic Review must be approved prior to approval of the building plans. Historic application/requirements can be found at: https://www.tucsonaz.gov/files/pdsd/Preservation/HPZ_Review_Application_Package_2020.pdf. Contact Jodie Brown with questions regarding the Historic Review at Jodie.Brown@tucsonaz.gov. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
07/05/2023 | PDSD Application Completeness | REVIEW COMPLETED |