Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0126-00124
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/05/2026 | Commercial Electrical Standard | APPROVED | Where subject to physical damage, conductors, raceways, equipment, and cables shall be protected. NEC 300.4 Protection Against Physical Damage, NEC110.27(B) Prevent Physical Damage. | ||
| 02/02/2026 | Outdoor Lighting Standard | NOT REQUIRED | no modifications to the outdoor lighting. | ||
| 02/25/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/19/2026 | Commercial Building Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0126-00124 ADDRESS/PARCEL: (2323 S PARK AV TUCSON, AZ 85713) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Should you have any questions about these Commercial Building comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976. COMMENTS: 1. STRUCTURAL a. Please submit structural drawing illustrating the anchoring system used for the pedestal. b. If bollards are used to protect the charging equipment, please provide structural drawing illustrating the footing required. 2. ENLARGED PLAN 3. On the plan, show the required clear floor areas for accessibility complying to ICC A117.1 - 2017 Accessible and Usable Building and Facilities (effective 1/1/26) a. Show accessible ramp to traverse the concrete curb. b. Locate the proper light source illuminating the ev charging area with code compliant lumen levels. i. Should pole light be installed, provide structural detail starting from the bottom with the drilled pier, light pole detail drawing, light head, specification that includes the lumen of light source to the kelvin temperature of the light source, etc. 4. Please resubmit. |
||
| 02/23/2026 | Site Engineering Standard | REQUIRES RESUBMIT | Site Engineering Review TC-COM-0126-00124 2323 S PARK AV Summary: Installation of electric vehicle charging station Site Engineering comments are as follows: 1. See Building Engineering reviewer’s comments regarding the necessity of lighting, an access ramp, and bollard design plan. To re-submit, visit the Tucson Development Center Online at: https://tdc-online.tucsonaz.gov/#/home The instructions for resubmittal can be found at: Revisions and Resubmittals Engineering Associate: Ryan Insalaco ryan.insalaco@tucsonaz.gov |
||
| 02/25/2026 | Site Zoning Standard | REQUIRES RESUBMIT | 1. COMMENT: Please address comments from the Commercial Building Code reviewer as they may affect the design of the improvement. Contact Fernando Garcia at fernando.garcia2@tucsonaz.gov. |
||
| 02/24/2026 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 02/02/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |