Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0126-00104
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/18/2026 | Commercial Building Standard | APPROVED | |||
| 03/18/2026 | Commercial Mechanical Standard | APPROVED | |||
| 03/03/2026 | Outdoor Lighting Standard | NOT REQUIRED | No modifications to the outdoor lighting. | ||
| 02/27/2026 | Site Engineering Standard | NOT REQUIRED | |||
| 03/18/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/03/2026 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0126-00104 (8554 E BROADWAY BL TUCSON, AZ 85710) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC). Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered design professional. Provide complete electrical plans, design, and calculations, sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, 2018 IBC section 107.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/checklists/commercial_submittal_requirements_july2023.pdf 2. Provide the complete set of electrical plans sealed by a qualified Electrical Engineer, Registered in the State of Arizona. Plans shall include (as necessary for scope of work), but may not be limited to items below: 3. Provide an electrical demo plan showing all removed electrical or lighting fixtures. 4. Show all wiring methods in detail for all new or modified branch circuit conductors and feeders. Conductor type and conduit size/type. Note wet use requirements. NEC arts;300 and 408.4. 5. Provide a panel schedules, showing the circuits that are being modified, added or removed or existing. NEC arts;300 and 408.4. Include panel bus rating and A.I.C. rating. IBC 107.1. 6. Designate the circuit number on the electrical plans, that corresponds to the panel schedule, at the location of each existing, new or modified light fixtures, receptacles, gate operator, and equipment disconnect switch, NEC arts;300 and 408.4. IBC 107.1. Each electrical outlet should be labeled by panel and circuit number. Additional comments may be forthcoming with complete electrical plans for the proposed site and electrical work. |
||
| 03/18/2026 | Commercial Plumbing Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0126-00104 ADDRESS/PARCEL: 8554 E BROADWAY BL TUCSON, AZ 85710 Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov COMMENTS: 1. Provide calculations to verify that the minimum plumbing facilities required by Table 2902.1, IBC 2024, have been provided. Reference: Sections 1109.5 and 2902.1, IBC 2024. |
||
| 03/12/2026 | Site Zoning Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Olga Salazar Planning & Development Services Department – Zoning Review Section PROJECT: TC-COM-0126-00104 – Commercial Building 8554 East Broadway Boulevard, Tucson, 85710 Plan Review (1st Review) TRANSMITTAL DATE: March 12, 2026 This site is zoned C-2 (UDC Section 4.7.21). “Alcoholic Beverage Service (bar)” is a permitted use in the C-2 zone. COMMENT: Add the following legal description under the project information on cover sheet: DESERT STEPPES ESTATES PTN N448' BLK H EXC W250' N320' & EXC N205' E154' W454' & EXC N180' E150”. COMMENT: On cover sheet, provide a general description of the project. COMMENT: Provide dimensions of the suite on the site plan. COMMENT: The existing suite is part of a shopping center that shares a parking lot with other businesses (Walmart, Bank of America, and Taco Bell), operating as a single site. A parking calculation table is required to demonstrate sufficient on-site parking to accommodate the proposed bar while ensuring that no more than 50% of the site's floor area is dedicated to uses with a parking formula of one space per 100 square feet of Gross Floor Area (GFA) or a more intense formula, maintaining the Shopping Center definition (UDC 11.3.9.C.3). Please provide a parking calculations table for the entire site, including the required parking for the proposed bar use, which per UDC Table 7.4.4-1, requires 1 parking space per 50 square feet of GFA. COMMENT: More comments may be forthcoming based on the next submittal's response. If you have any questions about this transmittal, please contact Olga Salazar at Olga.Salazar@tucsonaz.gov. |
||
| 03/18/2026 | Water - PDSD Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0126-00104 ADDRESS/PARCEL: 8554 E BROADWAY BL TUCSON, AZ 85710 Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov COMMENTS: 1. Provide the size of the water meter serving this location, the size of the backflow preventer associated with the water meter, and the total water demand served by the water meter. Reference: Section 107.2.1, IBC 2024. |
||
| 03/18/2026 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 02/27/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |