Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.3
Permit Number - TC-COM-0126-00045
Review Name: COMMERCIAL REVIEW - LIMITED v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/12/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/09/2026 | Commercial Building | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0126-00045 ADDRESS: (3202 N 1ST AV TUCSON, AZ 85719) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Should you have any questions about these Commercial Building comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976. COMMENTS: 1. CASHIER: Please provide drawing illustrating the following. a. The tops of work surfaces shall be 28 inches min & 34 inches max above the floor per ICC A117.1 sec 902.4. b. Sec 306.3.3 Knee clearance shall be 11 inches min in depth at 9 inches above the floor, and 8 inches min in depth at 27 inches above the floor. c. Sec 306.2.4 Additional toe clearance space extending greater than 6 inches beyond the available knee clearance at 9 inches above the floor. d. Sec 306.3 Knee clearance shall be 30 inches min in width. e. 904.3.2 Parallel approach, the counter surface 36 inches min length. f. 904.3.3 Forward approach, the counter surface 30 inches min length. 1. WATER CLOSET a. No other fixtures or obstructions shall be within the required water closet clearance. ICC A117.1 section 604.3.3 b. Clearance around a water closet shall be 60 inches minimum in width, measured perpendicular from the sidewall. ICC A117.1 section 604.3.1 c. Clearance around the water closet shall be 56 inches minimum in depth, measured perpendicular from the rear wall. ICC A117.1 section 604.3.2 Please submit. d. Please relocate the lavatory. 2. CODE VIOLATION CE-VIO1024-04017 a. Please include work required to comply to violations below. b. If permit has been applied for, please provide the building permit number. a. This parcel has many addresses, the business that had their power surrendered was 3202 N. 1st Ave. There have been many electrical hazards that has been identified at this commercial property. Two mini splits installed without permits. Unapproved wiring at the roof top energizing multiple business signs and other unknown electrical components. Portable laminar work lights permanently hard wired in non-code complaint manner. Extension cords being used in lieu of permanent wiring for unapproved interior illumination devices. Exterior outdoor lighting fixtures installed without permits. Business operating a used car sale lot and car rental business along with the retail smoke shop without an approved certificate of occupancy. Code Enforcement is requesting that all violations are abated with applicable permits and required inspections. 3. SIGN - Submit a separate permit for the sign. Please provide the sign permit number if already applied. 4, Please resubmit. |
||
| 01/28/2026 | Commercial Electrical | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0126-00045 (3202 N 1ST AV TUCSON, AZ 85719) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC). Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. The following permit, TC-COM-1125-02096, must be resolved and inspections completed prior to approval of this CFO permit. |
||
| 02/09/2026 | Commercial Mechanical | REQUIRES RESUBMIT | If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov. 1. Identify and show the locations of the installed HVAC appliances (e.g., rooftop units, mini-splits, exhaust fans, etc.). 2. Provide calculations to verify that the provided ventilation is adequate for a mercantile occupancy. (If smoking is to be allowed in areas of the facility, see “Smoking Lounges” in Table 403.3.1.1, IMC 2024 for guidance.) Reference: Section 403.3.1.1, IMC 2024. |
||
| 02/11/2026 | Site Engineering | REQUIRES RESUBMIT | Please see the Site Zoning reviewer's comment regarding proximity to the nearby charter school. Engineering Associate: Ryan Insalaco ryan.insalaco@tucsonaz.gov |
||
| 02/12/2026 | Site Engineering | REQUIRES RESUBMIT | |||
| 02/10/2026 | Site Zoning | REQUIRES RESUBMIT | 1. COMMENT: Provide a general note that indicates the zoning use for this location, which is "Retail Trade Use Group - Smoke Shop, subject to use-specific standards 4.9.9.H." 2. COMMENT: This smoke shop does not demonstrate compliance with use-specific standard 4.9.9.H, which requires that a smoke shop be located 1,000 feet away from any public, private, or charter school or childcare center. This smoke shop is less than 1,000 feet away from the Seneca Preparatory Academy, located on the campus of the Sacred Heart Church. As such, Site Zoning cannot approve this permit. Contact Fernando Garcia, Lead Planner, Site Zoning at fernando.garcia2@tucsonaz.gov. |
||
| 02/09/2026 | Water - PDSD | REQUIRES RESUBMIT | If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov. Show the location and the size of both the water service meter and the reduced pressure backflow preventer assembly. Reference: Section 107.2.1, IBC 2024. |
||
| 02/09/2026 | Commercial Plumbing | REVIEW COMPLETED | |||
| 02/10/2026 | Fire New Construction | REVIEW COMPLETED | |||
| 01/28/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |