Permit Number: TC-COM-0126-00022
Parcel: 12112056K

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0126-00022
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/16/2026 Commercial Building Standard APPROVED
01/16/2026 Commercial Electrical Standard APPROVED
01/29/2026 Commercial Plumbing Standard APPROVED
01/28/2026 Site Zoning Standard APPROVED
01/29/2026 Water - PDSD Standard APPROVED
01/15/2026 Outdoor Lighting Standard NOT REQUIRED No modifications to the outdoor lighting.
01/29/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/29/2026 Commercial Mechanical Standard REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0126-00022
ADDRESS/PARCEL: 5151 E SPEEDWAY BL TUCSON, AZ 85712

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov

COMMENTS:

1. Hood canopies shall extend at least 6” horizontally on all open sides beyond the edge of the top horizontal surface of the appliances (i.e. the pizza ovens) under the hood. Reference: Section 507.1.6.1, IMC 2024.
2. Revise detail A1/M501 to show how the new Type I hood is supported from the building structure. Reference: Sections 302.1 and 507.2.4, IMC 2024.
3. The mechanical plan, M102, shows two high velocity diffusers located in close proximity to the ends of the Type I hood. Verify that the location and type of air outlets complies with the hood manufacturer’s installation instructions and does not reduce the effectiveness of the exhaust system. Reference: Sections 304.1 and 508.1, IMC 2024.
01/12/2026 Site Engineering Standard REQUIRES RESUBMIT Site Engineering Review

TC-COM-0126-00022
5151 E SPEEDWAY BL

Summary: Includes reorganization of existing kitchen equipment and addition of new fryer units. The existing type 1 hood and wrapped ducts will be replaced with Type 1 new equipment. Rooftop equipment will remain existing.

Site Engineering comments are as follows:

1. This property lies within a recognized floodplain, Alamo Wash. Please apply for a floodplain use (FPU) permit in “Sub-Records” of permit TC-COM-0126-00022 on TDC-Online.tucsonaz.gov. Please upload a pdf of the site plan.
2. Please include a cost estimate breakdown of the project into separate lines, labor, materials/equipment, and warranties/fees associated with the project. Include the company/contractor’s letterhead on the document. This cost estimate will be used for substantial improvement calculations.

Instructions:

1) Navigate into the current project in the “My Work” tab. Within the permit, navigate to the “Sub-Records” tab and click “Apply” on the Floodplain Use Permit Sub-Record
2) Locations -> Confirm the location for the project is accurate. Click “Next”
3) Type -> Fill in the “Square Feet” and “Valuation” boxes with the project area and a contractor-provided cost estimate (See note above: for new structures, input 0). Click “Next”
4) Contacts -> Confirm contacts and add any additional contacts if applicable. Click “Next”
5) Attachments -> Please attach the project plan and supporting documentation for the cost estimate. Click “Next”
6) Signature -> Read the statement and type your name. Sign your name below (You may Enable Type Signature to have the software sign for you.) Click “Next”
7) Review and Submit -> Review all information to ensure accuracy. Click “Submit”

To re-submit, visit the Tucson Development Center Online at:
https://tdc-online.tucsonaz.gov/#/home

The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf

Engineering Associate: Ryan Insalaco
ryan.insalaco@tucsonaz.gov
01/28/2026 Fire New Construction Standard REVIEW COMPLETED
01/07/2026 PDSD Application Completeness Express REVIEW COMPLETED