Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.4
Permit Number - TC-COM-0125-00204
Review Name: COMMERCIAL REVIEW - LIMITED v.4
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/28/2025 | Commercial Electrical | APPROVED | |||
| 06/02/2025 | Commercial Structural | APPROVED | |||
| 06/05/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/03/2025 | Commercial Mechanical | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0125-00204 ADDRESS/PARCEL: (3142 N BALBOA AV Unit:UNIT 9 TUCSON, AZ 85705) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. COMMENTS: 1. SHEET A1.4 a. IRC Appendix T103.3 Solar-ready zone area shall not be less than 300 sf exclusive of mandatory access or setback areas per International Fire Code. b. Your plan shows 80 sf. c. Please correct this. 2. SHEET M1.1 a. HVAC system is illustrated along with the AHU on the roof, ducts, diffusers in living room/bedroom, (no diffuser in bathroom). b. However, your response to the comment is “Mini Split” is to be installed as illustrated in Sheet E1.3. Condenser outdoor and an indoor unit in just the living room, (no indoor unit in bedroom nor the bathroom). c. Please confirm what system you are using and correct your drawings to reflect this. 3. SHEET G1.1 & Water Heater a. Gas Plan shows a gas single line diagram to the water heater. b. Sheet P1.1 does show a standard 40 gallon water heater tank. i. However, to the left of the plumbing plan a water heater schedule is shown with an electric tankless water heater. ii. Sheet E1.4 Electrical Panel Schedule show a line item for a heater but shows it as a “Gas water heater”. Please correct this and ensure that only one system is chosen. 1. NOTE: This electrical panel schedule does not include the HVAC. Please correct this and correct the load calculation to include the HAVC system. 4. SHEET M2.1 a. The Manual J information indicates 21,700 BTUH as the sensible load required by the home. i. This is roughly a 2-ton unit. b. Your Manual S shows a Goodman with capacity of 48,000 BTUH. i. This is too big for the dwelling. ii. This means it will be very inefficient, it does not comply to the building code’s efficiency requirements. iii. Please correct this. 5. Please resubmit. If you have any questions about these comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976 |
||
| 06/03/2025 | Commercial Plumbing | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0125-00204 ADDRESS/PARCEL: (3142 N BALBOA AV Unit:UNIT 9 TUCSON, AZ 85705) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. COMMENTS: 1. SHEET A1.4 a. IRC Appendix T103.3 Solar-ready zone area shall not be less than 300 sf exclusive of mandatory access or setback areas per International Fire Code. b. Your plan shows 80 sf. c. Please correct this. 2. SHEET M1.1 a. HVAC system is illustrated along with the AHU on the roof, ducts, diffusers in living room/bedroom, (no diffuser in bathroom). b. However, your response to the comment is “Mini Split” is to be installed as illustrated in Sheet E1.3. Condenser outdoor and an indoor unit in just the living room, (no indoor unit in bedroom nor the bathroom). c. Please confirm what system you are using and correct your drawings to reflect this. 3. SHEET G1.1 & Water Heater a. Gas Plan shows a gas single line diagram to the water heater. b. Sheet P1.1 does show a standard 40 gallon water heater tank. i. However, to the left of the plumbing plan a water heater schedule is shown with an electric tankless water heater. ii. Sheet E1.4 Electrical Panel Schedule show a line item for a heater but shows it as a “Gas water heater”. Please correct this and ensure that only one system is chosen. 1. NOTE: This electrical panel schedule does not include the HVAC. Please correct this and correct the load calculation to include the HAVC system. 4. SHEET M2.1 a. The Manual J information indicates 21,700 BTUH as the sensible load required by the home. i. This is roughly a 2-ton unit. b. Your Manual S shows a Goodman with capacity of 48,000 BTUH. i. This is too big for the dwelling. ii. This means it will be very inefficient, it does not comply to the building code’s efficiency requirements. iii. Please correct this. 5. Please resubmit. If you have any questions about these comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976 |
||
| 06/05/2025 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-COM-0125-00204 - CE-VIO0624-02345 3142 N BALBOA AV Unit: 9 – O-3 Fire Damage Repair (2nd Review) TRANSMITTAL: June 5, 2025 Resubmittal requires a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the O-3 zone (UDC 4.7.15). A Mobile Home Parking is not an allowed use in the Zone, (UDC Table 4.8-3). This site is nonconforming for the use. 1. Based on the plans you are proposing an expansion of the bath and closet to the east side of the existing structure. As this site is considered a nonresidential use, UDC Article 6.6.3.B. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A Development Package (DP) meeting the requirements of the Checklist for Minor Changes to Commercial/Industrial Sites is required to be submitted and approved. The DP is a separate submittal from the building plans. The checklist can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/minor_changes_to_commercial_industrial_sites_.pdf. 2. Per UDC Table 6.3-3.A the minimum setback is the greater of ten (10) feet, or three-quarters (3/4) the height of the structure’s wall facing each interior property line. Based on a wall height of less than 13’-4” the required perimeter yard setback from the proposed addition to the north and east property line is 10’-0”, proposed setback to the north property line is 4.52’ and to the east property line is 7.41’. A Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 05/20/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |