Permit Review Detail
Review Status: In Review
Review Details: COMMERCIAL REVIEW - FULL REVISION v.1
Permit Number - TC-COM-0125-00202
Review Name: COMMERCIAL REVIEW - FULL REVISION v.1
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/01/2025 | Commercial Building Standard | APPROVED | Building (B) Reviewer Andrew Bevis; abevis@safebuilt.com Discipline Status:Approved As Is Date Completed: 11/20/2025 Structural (S) Reviewer Madeline Nelson; mnelson@safebuilt.com Discipline Status:Approved As Is Date Completed: 11/25/2025 |
||
| 12/01/2025 | Commercial Electrical Standard | APPROVED | Electrical (E) Reviewer Ron Ross; rross@safebuilt.com Discipline Status:Approved As Is Date Completed: 11/24/2025 |
||
| 12/01/2025 | Commercial Mechanical Standard | APPROVED | Mechanical (M) Reviewer Jorge Valido; jvalido@safebuilt.com Discipline Status:Approved As Is Date Completed: 11/21/2025 |
||
| 11/21/2025 | Site Engineering Standard | NOT REQUIRED | |||
| N/A | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| N/A | Fire New Construction Standard | PENDING ASSIGNMENT | |||
| N/A | Site Zoning Standard | PENDING ASSIGNMENT | |||
| N/A | Water - PDSD Standard | PENDING ASSIGNMENT | |||
| 12/01/2025 | Commercial Plumbing Standard | REQUIRES RESUBMIT | Plumbing (P) Reviewer Perry Hendershott; phendershott@safebuilt.com Discipline Status:Denied Date Completed: 11/30/2025 Plumbing Revision Review: 1).Plan Page A103: Missing the GPM load that each roof scupper/downspout is responsible for. Add the GPM load that each roof scupper/downspout is responsible for.-2018 IPC 1106.3, 1106.5, 1108.3 |
||
| 12/02/2025 | Outdoor Lighting Standard | REQUIRES RESUBMIT | Outdoor Lighting Review TC-COM-0125-00202 (1680 E TUCSON MARKETPLACE BL TUCSON, AZ 85713) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). Outdoor Lighting Review: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf a. Provide an outdoor site lighting plan that meets the requirements of OLC 104.2. Show/locate the different light sources on your site plan. Number the light fixtures on your lighting fixture table and use the same number on your site plan. This will require all exterior lights to be shown on the site exterior lighting plan, including site and parking lot lights. b. List the Lighting Area per OLC (typically E3) chapter 3 and used in Table 401.1. Specify the compliance option from Table 401.1 that is being used. Total outdoor light output shall not exceed the lumen limits listed in Table 401.1. c. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 104.2.1, 401.2. Include all exterior fixtures on the property in the calculations. List shielded and unshielded lights in the calculation. d. Show unshielded fixtures with a maximum of 3,000 lumens, OLC 401.4. e. Show lamps with a maximum of 3500K color temperature, OLC 402.1. f. Provide the manufacturer’s specification sheets for the outdoor lighting fixtures. Include the lumen and color temperature values for each outdoor fixture type. g. Indicate whether or not a special inspection is required per sec. 104.2.2, and 106.2. https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate_odl.pdf h. Specify any exceptions used. i. Provide Curfew lighting controls If applicable Per section 403. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 11/20/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |