Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.4
Permit Number - TC-COM-0125-00202
Review Name: COMMERCIAL REVIEW - FULL v.4
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/26/2025 | Commercial Electrical Standard | APPROVED | Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved Reason: Date Completed : 3/21/2025 6:55:36 PM |
||
| 03/26/2025 | Commercial Plumbing Standard | APPROVED | Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Approved Reason: Date Completed : 3/26/2025 9:55:24 AM |
||
| 03/26/2025 | Outdoor Lighting Standard | APPROVED | Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved Reason: Date Completed : 3/21/2025 6:55:36 PM |
||
| 04/14/2025 | Water - PDSD Standard | APPROVED | |||
| 04/14/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/26/2025 | Commercial Mechanical Standard | REQUIRES RESUBMIT | Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Denied Reason: Date Completed : 3/20/2025 6:48:07 PM 1. (RESOLVED) - General - Provide COMcheck Mechanical Compliance Certificate. Any other APPROVED agency is acceptable. - 2018 IECC Section C403.3.2 HVAC equipment performance requirements. 2. (UNRESOLVED) - General - Provide Heat Load Calculations. - 2018 IECC Section C403.1.1 Calculation of heating and cooling loads. i. Plan Sheet M005 - FCU2/HP2 system Checksums - Net Total 8876 BTU/h. - Plan Sheet M001 - states on the Total Capacity (MBH) 24.0 (24000 BTU/h). - The output capacity of heating and cooling equipment shall be not greater than that of the smallest available equipment size that exceeds the loads calculated in accordance with Section C403.1.1. - 2018 IECC - C403.3.1 Equipment sizing (Mandatory). 3. (RESOLVED) - Plan Sheet M002 - Detail #3 states on detail for Guest Laundry, PROVIDE MOTERIZED DAMPER INTREGAL WITH EXTERIOR LOUVER. (TYP.). Provide size for O/A Makeup Louver. Substantiate with calculations. - 2018 IMC Section 504.6 Makeup air. |
||
| 04/08/2025 | Site Engineering Standard | REQUIRES RESUBMIT | TC-COM-0125-00202 1680 E TUCSON MARKETPLACE BL The building permit cannot be approved until the associated development package, TD-DEV-0125-00003, is approved. |
||
| 04/04/2025 | Site Zoning Standard | REQUIRES RESUBMIT | FROM: Zoning Review Section PROJECT: TC-COM-0125-00202 - TD-DEV-0125-00003 1680 E TUCSON MARKETPLACE BL – PAD-15 Travelers Accommodation, Lodging (2nd Review) TRANSMITTAL DATE: April 4, 2025 This site is located in PAD-15, Travelers Accommodation, Lodging is an allowed use in the PAD. COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Comment: Zoning has reviewed the Hotel plans for compliance with Development Package (DP) TD-DEV-0125-00003 and all though the plans appear to match until the DP is approved by all review agencies Zoning cannot approve this permit. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 03/19/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |