Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0125-00195
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/24/2025 | Site Zoning Standard | APPROVED | |||
| 02/21/2025 | Site Landscape Standard | NOT REQUIRED | |||
| 03/17/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/17/2025 | Commercial Building Standard | REQUIRES RESUBMIT | February 7, 2025 1st Review Seaver Franks Architects Attn: Rick Huch/ Daren Sadowsky 2552 N. Alvernon Way Tucson, Arizona 85712 Re: STARR PASS GUEST SUITES REMODEL City of Tucson Permit Number: TC-COM-0125-00195 Stantec Project Number: 185215066 Stantec File Number: TUC-25-022 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms R-1 I-B 31,549 158 Yes Yes Separate Permits: Automatic fire sprinklers and fire alarm. Deferred Submittals: None. Special Inspections: None. ARCHITECTURAL COMMENTS Sheet A2.6 1. Please provide the listed fire-rated assembly for wall type C fire partition. [Ref. IBC 2018 Sec. 703.3] Sheet A2.7 1. The plans indicate a recessed niche proposed in the fire-rated partition separating sleeping units. Please provide a listed-fire rated assembly that will maintain the required 1-hour separation with the reduced wall width in that area. [Ref. IBC 2018 Sec. 703.3] Sheet A2.8 1. The plans indicate a recessed niche proposed in the fire-rated partition separating sleeping units. Please provide a listed-fire rated assembly that will maintain the required 1-hour separation with the reduced wall width in that area. [Ref. IBC 2018 Sec. 703.3] Sheet A2.9 1. The proposed wall type D indicated for the corridor/sleeping unit common wall is not rated. The corridor walls are required to be fire partitions with a minimum fire rating of 30 minutes. Please revise and provide a listed fire-rated assembly. [Ref. IBC 2018 Sec. 1020.1} Sheet A2.10 1. The proposed wall type D indicated for the corridor/sleeping unit common wall is not rated. The corridor walls are required to be fire partitions with a minimum fire rating of 30 minutes. Please revise and provide a listed fire-rated assembly. [Ref. IBC 2018 Sec. 1020.1} Sheet A2.11 1. The proposed wall type D indicated for the corridor/sleeping unit common wall is not rated. The corridor walls are required to be fire partitions with a minimum fire rating of 30 minutes. Please revise and provide a listed fire-rated assembly. [Ref. IBC 2018 Sec. 1020.1} STRUCTURAL COMMENTS There are no comments. MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS General 1. Please provide updated water pressure calculations due to the increase in plumbing fixtures. [Ref. IPC 2018 Sec. 604] ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
| 03/17/2025 | Commercial Electrical Standard | REQUIRES RESUBMIT | February 7, 2025 1st Review Seaver Franks Architects Attn: Rick Huch/ Daren Sadowsky 2552 N. Alvernon Way Tucson, Arizona 85712 Re: STARR PASS GUEST SUITES REMODEL City of Tucson Permit Number: TC-COM-0125-00195 Stantec Project Number: 185215066 Stantec File Number: TUC-25-022 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms R-1 I-B 31,549 158 Yes Yes Separate Permits: Automatic fire sprinklers and fire alarm. Deferred Submittals: None. Special Inspections: None. ARCHITECTURAL COMMENTS Sheet A2.6 1. Please provide the listed fire-rated assembly for wall type C fire partition. [Ref. IBC 2018 Sec. 703.3] Sheet A2.7 1. The plans indicate a recessed niche proposed in the fire-rated partition separating sleeping units. Please provide a listed-fire rated assembly that will maintain the required 1-hour separation with the reduced wall width in that area. [Ref. IBC 2018 Sec. 703.3] Sheet A2.8 1. The plans indicate a recessed niche proposed in the fire-rated partition separating sleeping units. Please provide a listed-fire rated assembly that will maintain the required 1-hour separation with the reduced wall width in that area. [Ref. IBC 2018 Sec. 703.3] Sheet A2.9 1. The proposed wall type D indicated for the corridor/sleeping unit common wall is not rated. The corridor walls are required to be fire partitions with a minimum fire rating of 30 minutes. Please revise and provide a listed fire-rated assembly. [Ref. IBC 2018 Sec. 1020.1} Sheet A2.10 1. The proposed wall type D indicated for the corridor/sleeping unit common wall is not rated. The corridor walls are required to be fire partitions with a minimum fire rating of 30 minutes. Please revise and provide a listed fire-rated assembly. [Ref. IBC 2018 Sec. 1020.1} Sheet A2.11 1. The proposed wall type D indicated for the corridor/sleeping unit common wall is not rated. The corridor walls are required to be fire partitions with a minimum fire rating of 30 minutes. Please revise and provide a listed fire-rated assembly. [Ref. IBC 2018 Sec. 1020.1} STRUCTURAL COMMENTS There are no comments. MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS General 1. Please provide updated water pressure calculations due to the increase in plumbing fixtures. [Ref. IPC 2018 Sec. 604] ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
| 03/17/2025 | Commercial Mechanical Standard | REQUIRES RESUBMIT | February 7, 2025 1st Review Seaver Franks Architects Attn: Rick Huch/ Daren Sadowsky 2552 N. Alvernon Way Tucson, Arizona 85712 Re: STARR PASS GUEST SUITES REMODEL City of Tucson Permit Number: TC-COM-0125-00195 Stantec Project Number: 185215066 Stantec File Number: TUC-25-022 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms R-1 I-B 31,549 158 Yes Yes Separate Permits: Automatic fire sprinklers and fire alarm. Deferred Submittals: None. Special Inspections: None. ARCHITECTURAL COMMENTS Sheet A2.6 1. Please provide the listed fire-rated assembly for wall type C fire partition. [Ref. IBC 2018 Sec. 703.3] Sheet A2.7 1. The plans indicate a recessed niche proposed in the fire-rated partition separating sleeping units. Please provide a listed-fire rated assembly that will maintain the required 1-hour separation with the reduced wall width in that area. [Ref. IBC 2018 Sec. 703.3] Sheet A2.8 1. The plans indicate a recessed niche proposed in the fire-rated partition separating sleeping units. Please provide a listed-fire rated assembly that will maintain the required 1-hour separation with the reduced wall width in that area. [Ref. IBC 2018 Sec. 703.3] Sheet A2.9 1. The proposed wall type D indicated for the corridor/sleeping unit common wall is not rated. The corridor walls are required to be fire partitions with a minimum fire rating of 30 minutes. Please revise and provide a listed fire-rated assembly. [Ref. IBC 2018 Sec. 1020.1} Sheet A2.10 1. The proposed wall type D indicated for the corridor/sleeping unit common wall is not rated. The corridor walls are required to be fire partitions with a minimum fire rating of 30 minutes. Please revise and provide a listed fire-rated assembly. [Ref. IBC 2018 Sec. 1020.1} Sheet A2.11 1. The proposed wall type D indicated for the corridor/sleeping unit common wall is not rated. The corridor walls are required to be fire partitions with a minimum fire rating of 30 minutes. Please revise and provide a listed fire-rated assembly. [Ref. IBC 2018 Sec. 1020.1} STRUCTURAL COMMENTS There are no comments. MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS General 1. Please provide updated water pressure calculations due to the increase in plumbing fixtures. [Ref. IPC 2018 Sec. 604] ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
| 03/17/2025 | Commercial Plumbing Standard | REQUIRES RESUBMIT | February 7, 2025 1st Review Seaver Franks Architects Attn: Rick Huch/ Daren Sadowsky 2552 N. Alvernon Way Tucson, Arizona 85712 Re: STARR PASS GUEST SUITES REMODEL City of Tucson Permit Number: TC-COM-0125-00195 Stantec Project Number: 185215066 Stantec File Number: TUC-25-022 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms R-1 I-B 31,549 158 Yes Yes Separate Permits: Automatic fire sprinklers and fire alarm. Deferred Submittals: None. Special Inspections: None. ARCHITECTURAL COMMENTS Sheet A2.6 1. Please provide the listed fire-rated assembly for wall type C fire partition. [Ref. IBC 2018 Sec. 703.3] Sheet A2.7 1. The plans indicate a recessed niche proposed in the fire-rated partition separating sleeping units. Please provide a listed-fire rated assembly that will maintain the required 1-hour separation with the reduced wall width in that area. [Ref. IBC 2018 Sec. 703.3] Sheet A2.8 1. The plans indicate a recessed niche proposed in the fire-rated partition separating sleeping units. Please provide a listed-fire rated assembly that will maintain the required 1-hour separation with the reduced wall width in that area. [Ref. IBC 2018 Sec. 703.3] Sheet A2.9 1. The proposed wall type D indicated for the corridor/sleeping unit common wall is not rated. The corridor walls are required to be fire partitions with a minimum fire rating of 30 minutes. Please revise and provide a listed fire-rated assembly. [Ref. IBC 2018 Sec. 1020.1} Sheet A2.10 1. The proposed wall type D indicated for the corridor/sleeping unit common wall is not rated. The corridor walls are required to be fire partitions with a minimum fire rating of 30 minutes. Please revise and provide a listed fire-rated assembly. [Ref. IBC 2018 Sec. 1020.1} Sheet A2.11 1. The proposed wall type D indicated for the corridor/sleeping unit common wall is not rated. The corridor walls are required to be fire partitions with a minimum fire rating of 30 minutes. Please revise and provide a listed fire-rated assembly. [Ref. IBC 2018 Sec. 1020.1} STRUCTURAL COMMENTS There are no comments. MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS General 1. Please provide updated water pressure calculations due to the increase in plumbing fixtures. [Ref. IPC 2018 Sec. 604] ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
| 02/10/2025 | Fire New Construction Standard | REVIEW COMPLETED | Fire alarm and fire sprinklers upgrades will required a separate permit. | ||
| 02/01/2025 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 02/24/2025 | Site Engineering Standard | REVIEW COMPLETED |