| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/20/2025 | Commercial Building | APPROVED | |||
| 02/20/2025 | Site Zoning | APPROVED | |||
| 02/24/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/06/2025 | Commercial Electrical | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0125-00152 (6255 E GRANT RD TUCSON, AZ 85712) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). General: 1. A signature and date are required as part of the Registrant Seal (Electrical). Section R4-30-304 of the Rules of the Arizona State Board of Technical Registration, states that in addition to signing the seal, the registrant shall include the date the document was sealed. Outdoor Lighting Code (OLC). 1. Additions or modifications to outdoor lighting less than 25% of total lighting shall require a complete inventory and site plan detailing all existing and any proposed new lighting, OLC 102.4. One additional outdoor is being added, lighting fixture “B”. 2. New or modified lighting shall meet the requirements of this code regarding shielding, and lamp type, OLC 102.4 3. Show lamps with a maximum of 3500K color temperature, OLC 402.1. Lighting fixture “B” shows a color temperature of 4,000K. 4. Submit catalogue or specification sheets of the proposed light fixture illustrating the type of fixture they are, and whether full cut-off or unshielded. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 02/13/2025 | Commercial Mechanical | REQUIRES RESUBMIT | 1. Provide plans sealed by an Arizona Registrant. Reference: Section 107.1, IBC 2018 and Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304. 2. Provide construction documents that are complete and clearly indicate the extent of the proposed work (i.e. remove the “FOR QA REVIEW, NOT FOR CONSTRUCTION” label from the drawings.). Reference: Section 107.2.1, IBC 2018. |
||
| 02/13/2025 | Commercial Plumbing | REQUIRES RESUBMIT | 1. Provide plans sealed by an Arizona Registrant. Reference: Section 107.1, IBC 2018 and Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304. 2. Provide construction documents that are complete and clearly indicate the extent of the proposed work (i.e. remove the “FOR QA REVIEW, NOT FOR CONSTRUCTION” label from the drawings.). Reference: Section 107.2.1, IBC 2018. 3. Provide a metering faucet for the lavatory, dispensing a maximum of 0.25 gallons per metering cycle (e.g. 0.5 GPM for 30 seconds). Verify that the faucet cycle will last for at least 10-seconds. Reference: Section 419.6, IPC 2018, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09. 4. Provide tempered water for the lavatories and public hand-washing sinks in restrooms using approved devices conforming to ASSE 1070. Reference: Sections 419.5 and 607.1.2, IPC 2018. 5. Verify that the distance from the hot water source to the hot water termination for the public lavatory complies with the requirements of Section C404.5, IECC 2018 (e.g., 24” for ½” pipe). |
||
| 02/05/2025 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 02/20/2025 | Site Engineering | REVIEW COMPLETED | |||
| 02/24/2025 | Site Engineering | REVIEW COMPLETED |