Permit Number: TC-COM-0125-00101
Parcel: 13343341C

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - LIMITED v.1

Permit Number - TC-COM-0125-00101
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/06/2025 Commercial Building APPROVED
01/31/2025 Commercial Electrical APPROVED
02/06/2025 Commercial Mechanical APPROVED
02/12/2025 Site Zoning APPROVED
02/06/2025 Water - PDSD APPROVED
01/31/2025 Outdoor Lighting NOT REQUIRED No changes to outdoor lighting.
02/12/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/06/2025 Commercial Plumbing REQUIRES RESUBMIT 1. Provide metering faucets for the lavatories, dispensing a maximum of 0.25 gallons per metering cycle (e.g. 0.5 GPM for 30 seconds). Verify that the faucet cycle will last for at least 10-seconds. Reference: Section 419.6, IPC 2018, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09.
2. Verify that the distance from the hot water source to the hot water termination for the public lavatories complies with the requirements of Section C404.5, IECC 2018 (i.e. the hot water source is within 24” of the ½” lavatory connection).
01/29/2025 Fire New Construction REVIEW COMPLETED Any alterations to the existing CO2 system requires a separate operational permit and review.
01/29/2025 PDSD Application Completeness Express REVIEW COMPLETED
02/12/2025 Site Engineering REVIEW COMPLETED