Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0125-00100
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/04/2025 | Outdoor Lighting Standard | NOT REQUIRED | No outdoor lighting changes. | ||
| 02/20/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/18/2025 | Commercial Building Standard | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. 1. Please amend the plans to provide a detailed description of the work involved in this permit’s scope. IBC 105.3 2. Please amend the plans to provide dimensioned distances between structures and adjacent lot lines. IBC 107.2.6 For example. Is the north wall on the property line, or is it set back. 3. Please amend the plans to provide parapet walls in accordance with IBC 705.11 and IBC 705.11.1 For example, where the Fire Separation Distance is less than 5 feet from the property line a parapet way is required. 4. Please amend plans to show the roof covering the assembly’s listed classification is shown. IBC 1505.1 5. Please amend plans to show how the roof framing is cross vented or entirely within the building thermal envelope. IBC 1202.2, 1202.3. 6. Please amend the plans to provide the following information on the elevation drawings: IBC 107.2.1 A. Grade plane, adjacent grade, floor, roof, and parapet heights are relatively dimensioned. IBC 107.2.1 7. Please amend plans to provide two building sections in orthogonal directions and shown to scale for each building and structure. IBC 107.2.1 to show the following information. IBC 107.2.1 A. Interior wall and ceiling finishes are specifically identified. IBC 801.1 B. Building thermal envelope information is shown and matches documentation. IECC C402.1, C407.4 C. Detail drawings and references are provided for the roofing system, to include drip edge and flashings. 8. Please amend plans to provide outside air ventilation calculations IMC 401, 402, 403, Table 403.3. and the method used for the ventilation. 9. Please provide the structural calculations, sealed by an Arizona licensed registrant, used in the design of this structure. IBC 107.2.7 10. Provide illumination for the means of egress, including the exit discharge per IBC 1008. Show compliance with the following: A. The means of egress shall be illuminated at all times the building space is occupied. B. The means of egress illumination level shall not be less than 1 foot-candle at the walking surface. C. The means of egress illumination shall be supplied by backup power (consisting of storage batteries, unit equipment, or an on-site generator) for a duration of not less than 90 minutes. IBC 1008.3 11. Please amend the plans to show the required Accessible features to include the following IBC Chapter 11. A. Accessible Route IBC 1103.1 B. Accessible Entrance IBC 1103.2 Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 02/04/2025 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0125-00100 (1421 S KOLB RD TUCSON, AZ 85710) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. Provide electrical load calculations, for the Main Service Panel, Per NEC 220.40. 2. Provide a panel schedule showing the circuits that are being modified and added. 3. Show all wiring methods in detail for all branch circuit wiring along with branch circuit and breaker panel designations and correlate with the panel schedules. NEC arts;300 and 408.4. 4. Provide GFCI protection per NEC 210.8(B)(8). Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 02/20/2025 | Site Engineering Standard | REQUIRES RESUBMIT | TC-COM-0125-00100 1421 S KOLB RD Site Engineering comments are as follows: 1. The directional arrows on the site views are incorrect as well as the labels of the elevations of the proposed building addition. Ryan Insalaco – ryan.insalaco@tucsonaz.gov |
||
| 02/19/2025 | Site Zoning Standard | REQUIRES RESUBMIT | FROM: Ramiro Olivarez PDSD Zoning Review Section PROJECT: TC-COM-0125-00100 1421 S KOLB RD – C-2 Tenant Improvement Vehicle Rental and Sales – Storage expansion (1st Review) TRANSMITTAL DATE: February 19, 2025 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the C-2 zone (UDC 4.7.21). Vehicle Rental and Sales is an allowed use in the zone (UDC Table 4.8-6). 1. As the proposed project is an expansion of the site a development package is required, UDC Article 3.3.3.G.2.c A development package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. The Administrative Manual can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes-and-Plans/Zoning-Code#section-1. If you have any questions about this transmittal, please contact Ramiro Olivarez at Ramiro.Olivarez@tucsonaz.gov |
||
| 01/29/2025 | Fire New Construction Standard | REVIEW COMPLETED | Add fire extinguishers as required per The 2018 IFC Section 906 | ||
| 01/29/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |