Permit Number: TC-COM-0124-00204
Parcel: 13106008A

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0124-00204
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/31/2024 Historic NOT REQUIRED Property is not historically designated within a district or individually. No historic review required.
03/04/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
02/13/2024 Commercial Electrical REQUIRES RESUBMIT Permit Review TC-COM-0124-00204 (2001 S CRAYCROFT RD TUCSON, AZ 85711)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC).


1. Provide a Grounding Electrode System at the detached structure per NEC 690.47.
2. Show grounding details for the mounting equipment and metal support frame, NEC690.43.


Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
03/04/2024 Commercial Structural REQUIRES RESUBMIT Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.
1. Please submit the drawings and structural calculations for the carport structure that the PV system is sitting on. Should the structure is of steel, an Licensed Arizona Structural Engineer must design generate the structure drawings as well as provide structural calculations along with his seal/signature/date on both drawings and calculations.
2. Please resubmit.
02/27/2024 Site Engineering REQUIRES RESUBMIT See zoning comment
02/15/2024 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
TC-COM-0124-00204
2001 S CRAYCROFT RD1209 – C-2
Food Service (1st Review)

TRANSMITTAL: February 15, 2024

Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the C-2 zone (UDC 4.7.21). Food Service: Excluding Soup Kitchens is a allowed use in the zone (UDC Table 4.8-4), subject to Use Specific Standards 4.9.4.M.1 and 4.9.13.P.

1. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of the Checklist for Minor Changes to Commercial/Industrial Sites is required to be submitted and approved. The DP is a separate submittal from the building plans. The checklist can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/minor_changes_to_commercial_industrial_sites_.pdf. A development package is a separate submittal and must be submitted and approved prior to approval of this plan.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
02/01/2024 Fire New Construction REVIEW COMPLETED
01/30/2024 PDSD Application Completeness REVIEW COMPLETED