Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-COM-0124-00204
Parcel: 13106008A

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-0124-00204
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/24/2024 Site Engineering NOT REQUIRED
05/01/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
04/17/2024 Commercial Electrical REQUIRES RESUBMIT Permit Review TC-COM-0124-00204 (2001 S CRAYCROFT RD TUCSON, AZ 85711)
2nd Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC).

1. Show grounding details for the mounting equipment and metal support frame, NEC690.43. Show the Grounding Conductor’s connection at the modules, mounting and metal support structure. These sheets need to be Sealed by the Electrical Engineer.
2. Wire ID 14 and 15, appear undersized for the given current. The AC wire calculation on sheet E-602 shows the conductor ampacity as less than the required circuit ampacity. Provide electrical load calculations showing the expected load is compatible with the given conductor sizes, Per NEC 220.40.
3. Further reviews will be completed when Zoning and Building comments have been addressed.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
05/01/2024 Commercial Structural REQUIRES RESUBMIT My comments for "Requires Resubmit" were not responded to. Allow me to copy and paste for your perusal.
Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. 1. Please submit the drawings and structural calculations for the carport structure that the PV system is sitting on. Should the structure is of steel, an Licensed Arizona Structural Engineer must design generate the structure drawings as well as provide structural calculations along with his seal/signature/date on both drawings and calculations. 2. Please resubmit.
04/26/2024 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: Wyatt Berger
Lead Planner

PROJECT: TC-COM-0124-00204
2001 South Craycroft Road – C-2
Food Service (2nd Review)

TRANSMITTAL DATE: April 26, 2024

Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed.

1. This comment has not been addressed. Per UDC 3.3.3.G.2.c, a site plan (development package) is required for building or structure additions such as proposed. A development package that meets the Checklist for Minor Development Changes to Existing Commercial/Industrial Sites is required: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/minor_changes_to_commercial_industrial_sites_.pdf.

The development package is a separate submittal and shall be applied for through the Tucson Development Center Online under application type “Development Package.” Zoning cannot approve TC-COM-0124-00204 until the submitted development package has been approved by all reviewers.

If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951.
04/01/2024 PDSD Application Completeness REVIEW COMPLETED