Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0124-00184
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/08/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/08/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Madeline Nelson mnelson@safebuilt.com Denied Reason: Date Completed : 3/7/2024 5:04:40 PM 1. UNRESOLVED - FIRM REGISTRATION: Per the Arizona Revised Statutes, Chapter 32, Rule 141, a firm shall not engage in the practice of any board-regulated profession or occupation unless the firm is registered with the board”. This includes firms operating as sole proprietorships. To register, please fill out the form at the link below and mail it to the State of Arizona Board of Technical Registration located at 1110 W. Washington Street, Suite 240, Phoenix, AZ 85007. https://btr.az.gov/sites/default/files/2022-10/firm_annual_registration_9.22.22.pdf Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 3/5/2024 12:07:58 PM Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Approved Reason: Date Completed : 3/6/2024 2:30:26 PM 1. General - Add to Cover Sheet The Conveyer System conforms to 2018 IBC Chapter 30 - Elevators and Conveying Systems - Section 3004 and ASME B20.1 - (RESOLVED) Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved with Comments Reason: Date Completed : 3/5/2024 10:01:22 AM Electrical Review of FedEx By: Ron Ross PE A2422-PER101: Comment only: 2, 3, and 5 Hp motors all seem to be overloaded for 480V motors. A2422-PER401: Should have shown Panel PDP2 and indicate motor/vfd locations. Fortunately, Sheets ED1.3 and ED1.5 do show locations. If this information had not been provided, the electrical application would have been denied. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Approved with Comments Reason: Date Completed : 3/7/2024 12:22:00 AM Second Plumbing Review: No Plumbing Work shown Resolved-1). Need to address Building Plan Review comment #1 -2018 IPC 403.1 |
||
| 03/04/2024 | Fire New Construction | REVIEW COMPLETED | |||
| 03/01/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |