Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL FENCE/WALL v.1
Permit Number - TC-COM-0124-00178
Review Name: COMMERCIAL FENCE/WALL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/12/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/12/2024 | Commercial Building | REQUIRES RESUBMIT | Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. 1. Submit detail drawings illustrating properly sized posts and footing allowing for example the gate to be carried by the post and be able to swing open and close as a structurally sound installation. Reference: Section 107.1, IBC 2018 2. On your drawing, locate and label the location of sensors as well as the location of the equipment. 3. Locate and label the location of the knox box for fire use. 4. Once again for the rolling gate, provide drawings illustrating what the gate looks like as well as is it rolling north or is it south. Where are the structural posts, locate and label them. Show the location of the track, location of the knox box, sensor, etx. 5. Please resubmit. |
||
| 02/08/2024 | Commercial Electrical | REQUIRES RESUBMIT | Please address the electrical plan review comments and provide a written response 1. This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered design professional. Provide complete electrical plans, design, and calculations, sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, 2018 IBC section 107.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements |
||
| 02/08/2024 | Site Engineering | REQUIRES RESUBMIT | See zoning comment | ||
| 01/30/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-COM-0124-00178 2505 N DODGE BL. – R-2 ENTRY ACCESS GATES (1st Review) TRANSMITTAL DATE: January 30, 2024 Please resubmit revised drawings detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-2 zone (UDC 4.7.9). Multifamily is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. 1. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of the Checklist for Minor Changes to Commercial/Industrial Sites is required to be submitted and approved. The DP is a separate submittal from the building plans. The checklist can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/minor_changes_to_commercial_industrial_sites_.pdf. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 01/30/2024 | Fire New Construction | REVIEW COMPLETED | |||
| 01/29/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |