| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/06/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/22/2025 | Commercial Electrical | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0124-00178 (2505 N DODGE BL TUCSON, AZ 85716) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. The Panel Schedules on sheets E3.2 and E3.3 show the new panels with AIC ratings of 10K. 2. Provide Available Fault Current calculations from TEP transformer to all new equipment, 2017 NEC 110.24. 3. Show Panel’s and other equipment with AIC ratings greater than or equal to the Available Fault Currents, 2017 NEC 110.10. 4. Provide and show the disconnecting means for the Gate Operators or Controllers. 5. Provide electrical load calculations, for the Main Services, Per NEC 220.40. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 05/06/2025 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-COM-0124-00178 2505 N DODGE BL. – R-2 ENTRY ACCESS GATES (3rd Review) TRANSMITTAL DATE: May 6, 2025 Please resubmit revised drawings detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-2 zone (UDC 4.7.9). Multifamily is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. 1. Zoning acknowledges that development package (DP) TD-DEV-0425-00114 has been submitted for review. As the DP has not completed the first review Zoning cannot review the building plans for compliance with the DP and will review on the next submittal. Until the DP is approved by all review agencies Zoning cannot approve this permit. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 04/22/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |