Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0124-00141
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
02/01/2024 | Commercial Electrical | APPROVED | |||
02/06/2024 | Commercial Plumbing | APPROVED | |||
02/06/2024 | Water - PDSD | APPROVED | |||
02/05/2024 | Site Engineering | NOT REQUIRED | |||
02/07/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
02/07/2024 | Commercial Building | REQUIRES RESUBMIT | Please submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. 1. Please verify and amend the Scope of Work or amend the Existing Floor Plan as the Rest Room is on the Existing Floor plan. IBC 107.2 2. Please provide a demo plan to include any concrete removal and trenching for plumbing if applicable IBC 107.2 3. Please amend plans to provide the type, size and spacing of the fasteners to be used at the wall to roof structure shown in detail 6/A4.0 IBC 107.2 4. Please amend plans to indicate if the Roof Top Unit (RTU) is a replacement for an existing RTU. If so, provide the weight of existing RTU to be removed and a comparison to the new RTU’s weight. If the new RTU weighs less than the existing, removed RTU all is good. However, if this is a new RTU or a replacement that is heavier than the removed unit, provide an engineering evaluation from an Arizona registered engineer to indicate the existing roof structure can support the new RTU to include calculations, plans/details for the support of such equipment. IBC 107.2 Mark Masek Plans Examiner Mark.masek@tucsonaz.gov 520-837-4994 |
||
02/06/2024 | Commercial Mechanical | REQUIRES RESUBMIT | 1. Footnote b on Table 403.3.1.1, IMC 2018 states that mechanical exhaust is required for the beauty salon and no air from the beauty salon may be recirculated to any other space. HP-1 appears to be recirculating air from the beauty salon to the public restroom, break room, and to the reception room. Reference: Section 403.2.1 (3), IMC 2018. 2. Clarify the exhaust airflow rate. The Exhaust Fan Schedule calls for 500 CFM of exhaust but the mechanical floor plan calls out only 400 CFM of exhaust. Reference: Section 107.2.1, IBC 2018. |
||
01/25/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: TC-COM-0124-00141 2547 E BROADWAY BL Zoning C-1 TRANSMITTAL DATE: December 5, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: Clarify the use, based on the last approved Development package the use is retail. If you have any questions about this transmittal, Contact Zone1.desk@tucsonaz.gov |
||
01/30/2024 | Fire New Construction | REVIEW COMPLETED | |||
01/24/2024 | PDSD Application Completeness | REVIEW COMPLETED |