Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0124-00114
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/22/2024 | Site Zoning | APPROVED | SAME CONSTRUCTION PLANS ON PERMITS: TC-COM-0124-00064 (5402 E 30TH ST Unit:BLDG C UNIT 8 TUCSON, AZ 85711), TC-COM-0124-00114 (5402 E 30TH ST Unit:BLDG C UNIT 9 TUCSON, AZ 85711), TC-COM-0124-00115 (5402 E 30TH ST Unit:BLDG C UNIT 10 TUCSON, AZ 85711) SPECS AND OTHER DOCS MAY DIFFER. WITH SPECIFIC ADDRESSES ASSIGNED TO EACH SET |
||
| 02/13/2024 | Site Engineering | NOT REQUIRED | SAME CONSTRUCTION PLANS ON PERMITS: TC-COM-0124-00064 (5402 E 30TH ST Unit:BLDG C UNIT 8 TUCSON, AZ 85711), TC-COM-0124-00114 (5402 E 30TH ST Unit:BLDG C UNIT 9 TUCSON, AZ 85711), TC-COM-0124-00115 (5402 E 30TH ST Unit:BLDG C UNIT 10 TUCSON, AZ 85711) SPECS AND OTHER DOCS MAY DIFFER. WITH SPECIFIC ADDRESSES ASSIGNED TO EACH SET |
||
| 02/13/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | SAME CONSTRUCTION PLANS ON PERMITS: TC-COM-0124-00064 (5402 E 30TH ST Unit:BLDG C UNIT 8 TUCSON, AZ 85711), TC-COM-0124-00114 (5402 E 30TH ST Unit:BLDG C UNIT 9 TUCSON, AZ 85711), TC-COM-0124-00115 (5402 E 30TH ST Unit:BLDG C UNIT 10 TUCSON, AZ 85711) SPECS AND OTHER DOCS MAY DIFFER. WITH SPECIFIC ADDRESSES ASSIGNED TO EACH SET |
||
| 01/23/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 1/23/2024 12:13:29 PM Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 1/23/2024 12:13:17 PM Mechanical(M) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 1/23/2024 12:13:23 PM Electrical(E) Reviewer Andrew Bevis abevis@safebuilt.com Denied Reason: Date Completed : 1/23/2024 11:59:53 AM 1. General: Please provide a prescriptive path or provide COMcheck calculations for the lighting. All mandatory requirements must be identified on the plans for compliance. Reference 2018 IECC Section 505.1. Plumbing(P) Reviewer Andrew Bevis abevis@safebuilt.com Denied Reason: Date Completed : 1/23/2024 12:12:04 PM 1. Sheet P1.0: The gas riser diagram does not indicate the design information required to complete a thorough review on the gas supply system. Provide the following information: lengths of gas piping from supply to outlets, inlet pressure, Pressure drop and specific gravity used in the design of this system in accordance with the 2018 IFGC. |
||
| 01/19/2024 | Fire New Construction | REVIEW COMPLETED | SAME CONSTRUCTION PLANS ON PERMITS: TC-COM-0124-00064 (5402 E 30TH ST Unit:BLDG C UNIT 8 TUCSON, AZ 85711), TC-COM-0124-00114 (5402 E 30TH ST Unit:BLDG C UNIT 9 TUCSON, AZ 85711), TC-COM-0124-00115 (5402 E 30TH ST Unit:BLDG C UNIT 10 TUCSON, AZ 85711) SPECS AND OTHER DOCS MAY DIFFER. WITH SPECIFIC ADDRESSES ASSIGNED TO EACH SET |
||
| 01/19/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |