Permit Number: TC-COM-0124-00113
Parcel: 13007001B

Address:
3840 E 22ND ST

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - LIMITED v.1

Permit Number - TC-COM-0124-00113
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/01/2024 Commercial Electrical APPROVED
01/18/2024 Site Zoning APPROVED
01/30/2024 Water - PDSD APPROVED
01/30/2024 Commercial Mechanical NOT REQUIRED
01/30/2024 Site Engineering NOT REQUIRED
02/05/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/05/2024 Commercial Building REQUIRES RESUBMIT Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.
1. Submit drawings at the counter illustrating accessibility to include the height and width requirements.
2. Ensure that the facility is accessible complying to the ICC/ANSI A117.1 for both Employees and Customers.
3. Submit drawings illustrating the following. A minimum 0.019-inch (No. 26 galvanized sheet gage), corrosion-resistant weep screed with a minimum vertical attachment flange of 3 1/2 inches shall be provided at or below the foundation plate line on exterior stud walls. The weep screed shall be placed not less than 4 inches above the earth or 2 inches above paved areas and be of a type that will allow trapped water to drain to the exterior of the building. The water-resistive barrier shall lap the attachment flange. The exterior lath shall cover and
terminate on the attachment flange of the weep screed.
Per IBC 2512.1.2 Weep screeds
Where porches, landings, garage aprons are located at same level as floor slab, provide concrete or CMU foundation curb or other approved means to achieve minimum 2 inch clearance between slab and stucco weep screed.
4. Please resubmit
01/30/2024 Commercial Plumbing REQUIRES RESUBMIT Relocating the coffee bar may result in the need for an indirect waste receptor (i.e. a floor sink) to serve the coffee bar. If so, verify that one is either existing or show how one will be added to the area. Reference: Section 107.2.1, IBC 2018.
01/19/2024 Fire New Construction REVIEW COMPLETED
01/18/2024 PDSD Application Completeness Express REVIEW COMPLETED