Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0124-00113
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/01/2024 | Commercial Electrical | APPROVED | |||
| 01/18/2024 | Site Zoning | APPROVED | |||
| 01/30/2024 | Water - PDSD | APPROVED | |||
| 01/30/2024 | Commercial Mechanical | NOT REQUIRED | |||
| 01/30/2024 | Site Engineering | NOT REQUIRED | |||
| 02/05/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/05/2024 | Commercial Building | REQUIRES RESUBMIT | Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. 1. Submit drawings at the counter illustrating accessibility to include the height and width requirements. 2. Ensure that the facility is accessible complying to the ICC/ANSI A117.1 for both Employees and Customers. 3. Submit drawings illustrating the following. A minimum 0.019-inch (No. 26 galvanized sheet gage), corrosion-resistant weep screed with a minimum vertical attachment flange of 3 1/2 inches shall be provided at or below the foundation plate line on exterior stud walls. The weep screed shall be placed not less than 4 inches above the earth or 2 inches above paved areas and be of a type that will allow trapped water to drain to the exterior of the building. The water-resistive barrier shall lap the attachment flange. The exterior lath shall cover and terminate on the attachment flange of the weep screed. Per IBC 2512.1.2 Weep screeds Where porches, landings, garage aprons are located at same level as floor slab, provide concrete or CMU foundation curb or other approved means to achieve minimum 2 inch clearance between slab and stucco weep screed. 4. Please resubmit |
||
| 01/30/2024 | Commercial Plumbing | REQUIRES RESUBMIT | Relocating the coffee bar may result in the need for an indirect waste receptor (i.e. a floor sink) to serve the coffee bar. If so, verify that one is either existing or show how one will be added to the area. Reference: Section 107.2.1, IBC 2018. | ||
| 01/19/2024 | Fire New Construction | REVIEW COMPLETED | |||
| 01/18/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |