Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1
Permit Number - TC-COM-0124-00024
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/18/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
01/18/2024 | Commercial Plumbing | REQUIRES RESUBMIT | 1. Provide plans sealed by an Arizona Registrant. Reference: Section 107.1, IBC 2018 and Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304. 2. Specify the materials used for the gas piping (e.g. SDR of the proposed polyethylene pipe). Reference: Section 403.1, IFGC 2018. 3. Provide natural gas pipe sizing calculations. Include the gas pressure and the maximum pressure drop on the plans. Reference: Section 402.3, IFGC 2018. 4. Provide an accessible shut off valve for each appliance. Reference: Section 409.5, IFGC 2018. |
||
01/05/2024 | PDSD Application Completeness | REVIEW COMPLETED |