Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0124-00009
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/31/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 01/09/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Kimiyoshi Shimabukuro kshimabukuro@safebuilt.com Denied Reason: Date Completed : 1/6/2024 11:30:36 PM 1. Sheet S2.0 – The function of spaces are note labeled in foundation plan. Is it a storage? 2. Sheet S4.0 – Column footing detail 101/S4.0 doesn’t specify anchor size and depth. 3. Is the metal shop drawing deferred submittal then state so Building(B) Reviewer Kimiyoshi Shimabukuro kshimabukuro@safebuilt.com Denied Reason: Date Completed : 1/6/2024 11:32:10 PM 1. Architectural sheet – Provide narrative/descriptive scope of work relevant to this construction permit. 2. Architectural sheet – Provide/select applicable City of Tucson building codes: City of Tucson IBC Local Amendments • Amendments to the 2018 International Building Code • Amendments to the 2018 International Existing Building Code • Amendments to the 2018 International Energy Conservation Code • Amendments to the 2018 International Fuel Gas Code • Amendments to the 2018 International Mechanical Code • Amendments to the 2018 International Plumbing Code • Amendments to the 2018 International Residential Code • Amendments to the 2018 International Swimming Pool & Spa Code • Amendments to the 2017 National Electrical Code • Amendments to the 2018 International Fire Code • City of Tucson/Pima County Outdoor Lighting Code • Arizona Administrative Code Title 18 Chapter 5 for public and semi-public swimming pools • ICC A117.1 - 2009 Accessible and Usable Buildings and Facilities (by reference) Adopting Local Amendments to the Building Code is authorized by Ordinance #11590. 3. Architectural sheet - Provide building code analysis of this facility per 2018 International Building Code: Provide existing and new building area (SF), occupancy classification (S-2?), construction type, total occupancy load, and any sprinkler and/or fire alarm system. 4. Architectural sheet – List any deferred submittals and/or separate permits. 5. Architectural sheet – Provide project site plan showing building fire separation distances accordance with 2018 International Building Code from the proposed addition. 6. Architectural sheet – Provide the total occupancy load calculation and required and provided plumbing fixtures such as water closets, lavatories, drinking fountain and service sink for men and women per 2018 International Building Code chapter 29 table 2902.1. 7. Architectural sheet – Provide exterior elevations of all sides and building sections that shows building height, ceiling height, material finish, etc. 8. Architectural sheet – Provide reflected ceiling plan showing ceiling height, finish material and scope of electrical lighting if any. 9. Architectural sheet – Is the building occupancy a storage? If so, what is being stored? Any hazardous materials mentioned in 2018 International Building Code section 414? 10. Architectural sheet – Provide roof plan. Show roofing material drainage method described in 2018 International Building Code chapter 15. Mechanical N/A Electrical N/A Plumbing N/A |
||
| 01/18/2024 | Fire New Construction | REQUIRES RESUBMIT | Address SAFEBuilt comments. Questions: patricia.shelton@tucsonaz.gov |
||
| 01/31/2024 | Site Engineering | REQUIRES RESUBMIT | See zoning comment | ||
| 01/04/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: TC-COM-0124-00009 3190 W EL CAMINO DEL CERRO Zoning: I-2 TRANSMITTAL DATE:January 4, 2024 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: As you are proposing a canopy, the following comment is applicable. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. The DP is a separate submittal from the building plans. The DP will need to be approved prior to approval of this building permit. If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
| 01/04/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |