Permit Review Detail
Review Status: Approved
Review Details: RESTAMP - COMMERCIAL v.1
Permit Number - TC-COM-0124-00004
Review Name: RESTAMP - COMMERCIAL v.1
Review Status: Approved
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/09/2024 | External Reviewers - Willdan | APPROVED | APPROVED AS NOTED: • Provide special inspection form to AHJ as applicable for post installed anchors and rebar as noted in structural plan notes • If Ramp rise in elevation exceeds 6", handrail on both sides will be required IBC 1012.8 • Max slope on new means of egress ramps to be 1 in 12 (max 8% slope) |
||
| 05/03/2024 | Water - PDSD | APPROVED | |||
| 05/09/2024 | Bldg Permits - Post Review Express | REVIEW COMPLETED | |||
| 05/01/2024 | Fire New Construction | REVIEW COMPLETED |