Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.3
Permit Number - TC-COM-0123-00462
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/21/2023 | Site Engineering | APPROVED | |||
| 08/11/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/27/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-COM-0123-00462 1000 West Congress Street – C-1 Pueblo Vida (3rd Review) TRANSMITTAL DATE: July 27, 2023 Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Zoning has reviewed building permit TC-COM-0123-00462; however, zoning cannot approve this building permit until development package case number TD-DEV-1222-00074 has been approved by all review agencies. 2. Sheet TS does not match the site plan approved through development package case number TD-DEV-1222-00074. Of particular concern are the proposed entry canopy, fireplaces, walk-in refrigerator, water harvesting cistern, and tree rings shown on Sheet TS, as well as the removal of the required short- and long-term bicycle parking facilities. Either TD-DEV-1222-00074 will need to be revised to show these changes, or these changes shall be removed from the building permit plan set. Contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951 should you have questions about my transmittal. |
||
| 07/24/2023 | External Reviewers - SAFEBuilt | REVIEW COMPLETED | Structural(S) Reviewer Daljit Benipal dbenipal@safebuilt.com Conditionally Approved Reason: Date Completed : 3/16/2023 4:09:52 PM NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances. Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 7/19/2023 2:36:58 PM Mechanical(M) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 7/19/2023 2:37:11 PM Electrical(E) Reviewer (from previous submittal TUC9182001.030623) Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 3/15/2023 3:06:56 PM Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Conditionally Approved Reason: Date Completed : 7/22/2023 11:13:59 AM Second Plumbing Review: BLDG #1** SEE APPROVED APPEAL FOR GENDERLESS RESTROOM BY CBO CLAYTON TREVILLYAN **** SEE UPLOADED DOCUMENT=SUBJECT TO FIELD INSPECTIONS**** 1). OK 2).OK 3).OK -This occupancy type & load requires separate mens & womens restrooms, update all affected pages' -IPC 403.2** SEE APPROVED APPEAL FOR GENDERLESS RESTROOM BY CBO CLAYTON TREVILLYAN **** SEE UPLOADED DOCUMENT=SUBJECT TO FIELD INSPECTIONS**** 4).OK 5). OK-Add fixture spacing measurements for the lavs & toilets on plan page A4.2 -IPC 404.2, 405.3.1=OK SUBJECT TO FIELD INSPECTIONS**** 6). OK 7). OK 8). OK |
||
| 08/11/2023 | Historic | REVIEW COMPLETED | Historic demolition documentation provided. | ||
| 07/18/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |