Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0123-00428
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
02/01/2023 | Site Zoning | APPROVED | Please note that the removal of the exterior shade canopies requires a separate demolition permit. | ||
02/13/2023 | Site Engineering | NOT REQUIRED | |||
02/13/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
02/11/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0123-00428 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Conditionally Approved NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances. BUILDING REVIEW COMMENTS: Denied INCLUDE THE ALLOWED AND ACTUAL AREA, HEIGHT, AND STORY CALCULATIONS SHOW CORRECT CONSTRUCTION TYPE. SHOW THE FULL MEANS OF EGRESS TRAVEL DISTANCE TO THE BUILDING EXIT. INCLUDE THE NEW AND EXISTING EXIT SIGNS AND EMERGENCY LIGHTING MEETING THE REQUIREMENTS OF SECTION 1008 INCLUDING THE EXIT DISCHARGE LIGHTING. DETAIL FIRE-RATED WALL ASSEMBLIES AND THE USES OF THE ADJACENT SPACES FOR POSSIBLE SEPARATION. SHOW ACCESSIBLE DRESSING ROOMS MEETING THE DETAILS OF SECTION 803 AND THE DOOR SWING REQUIREMENTS OF SECTION 803.3 SHOW THE ACCESSIBLE ROUTE FROM THE ADA PARKING SPACES TO THE ENTRANCES. PENDING THE RESULTS OF THE PLUMBING AND OTHER REVIEWS. MECHANICAL REVIEW COMMENTS: Conditionally Approved Approved/Subject to field approval ELECTRICAL REVIEW COMMENTS Conditionally Approved E2.10: May want to update General Note E with specific height requirements PLUMBING REVIEW COMMENTS: N/A If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
||
01/30/2023 | Fire New Construction | REVIEW COMPLETED | |||
01/25/2023 | PDSD Application Completeness | REVIEW COMPLETED |