Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0123-00422
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/12/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
04/06/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0123-00422 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: APPROVED BUILDING REVIEW COMMENTS: APPROVED MECHANICAL REVIEW COMMENTS: N/A ELECTRICAL REVIEW COMMENTS DENIED 1. Indicate the location of the existing and new emergency lighting in the event of a power failure with battery backup on the plans. 2018 IBC 1008.3.1. - Comment not addressed: Only the new rooms emergency lighting was shown. Indicate the existing life safety emergency wall pack or other lighting in the open area that illuminates the exits. If there are no such fixtures existing in place, indicate new fixtures will be installed. 2. Indicate the location of all existing or new “night lighting” on the reflected ceiling plan for egress illumination or indicate light sensors will be used. All rooms and usable floor surfaces in a building shall be equipped with artificial lighting and shall be illuminated at all times that the space is occupied. 2018 IBC 1008.2. - Comment not addressed: Indicate the location of the lighting in the existing open area that fulfills this requirement. 3. Indicate the location of an existing emergency light on the exterior at the exit doors to illuminate the landings or indicate new fixtures will be provided. 2018 IBC 1008.3.2 (5). - Comment not addressed: No emergency lighting was shown on the exterior of the building. Show the location of existing emergency lighting (such as a remote head or soffit light on an em circuit) or indicate a new fixture will be installed. PLUMBING REVIEW COMMENTS: N/A If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
||
04/12/2023 | Fire New Construction | REVIEW COMPLETED | |||
03/21/2023 | PDSD Application Completeness | REVIEW COMPLETED |