Permit Number: TC-COM-0123-00401
Parcel: 108193190

Address:
715 E WETMORE RD

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.3

Permit Number - TC-COM-0123-00401
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/25/2024 Commercial Building APPROVED Drive thru structures - engineering (Sbux canopies)
03/25/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/20/2024 Commercial Electrical REQUIRES RESUBMIT 1 Provide detailed information as to the electrical branch circuit wiring source and wiring methods. NEC art 600.

2 The menu board itself will require a Sign permit.

Ref; 2018 IBC section 107.2.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements.
03/21/2024 Signs REQUIRES RESUBMIT RE: drive thru signage review
For: Starbucks - sign relocations
AT: 715 E Wetmore Road
Building permit: TC-COM-0123-00401
Date: 3/21/24
Reviewer: H. Thrall (Heather.Thrall@tucsonaz.gov)

Codes: Unified Development Code (UDC 7 and 7A), NEC 600, Outdoor Lighting Code (OLC) and International Building Code (IBC) 2018:

1. Acknowledged the desired relocations of the drive thru signage for this establishment. The following items are required for the permit record, as the structures are treated as new signs for technical code purposes.

2. Per UDC 7.4.6.F.2.a., add note "all drive thru signage structures shall be 1 foot from face of drive thru curb to leading edge of sign structure."

3. Per UDC 7A., add note - total sign area on menu station cabinet and digital cabinet within the order station.

4. Per NEC 600 - add following notes:
A) dedicated sign circuit shall be provided and labeled clearly at power panel
B) UL / MET equiv. sticker, manufacturer and installer sticker to be on sign structures

5. Per OLC: - add following notes to the plan:
A) signs shall not exceed 4400k color temperature
B) digital order station shall dim to 200 Nits from sunset to curfew - call out methods for dimming, i.e. photocell and timer together.
C) a timing device shall be provided to control all signs
D) timer shall shut all signs off at midnight curfew

6. General safety notes:
A) all digital sign components shall be compliant with Federal Communication Commission requirements to not interrupt small cellular wireless services
B) all detached signs shall be 2' from driveway curbs, 5' from fire hydrants, 18" from adjacent parking and 1' from face of drive thru lane curbing to structure

An Arizona licensed electrician or sign contractor is required to be added to this permit package prior to permit issuance. Email me at Heather.Thrall@tucsonaz.gov if you have any questions.
03/21/2024 Site Zoning REQUIRES RESUBMIT FROM: Nathan Herrera
PDSD Zoning Review Section

PROJECT: TC-COM-0123-00401
715 E WETMORE RD Zoning C-3

TRANSMITTAL DATE:‎ March 21, 2024


COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

1.COMMENT: The proposed scope of work is for a signs permit. Zoning cannot approve of this permit until the Signs review is complete and approved.

Please contact Heather Thrall for more information on the requirements at Heather.Thrall@tucsonaz.gov or phone at (520) 837-4961.

If you have any questions about this transmittal, Contact Nathan Herrera at Nathan.Herrera@tucsonaz.gov
02/21/2024 PDSD Application Completeness Express REVIEW COMPLETED