Review Status: Approved
Review Details: BUILDING OFFICIAL APPEAL REVIEW v.1
Plan Number - TC-BCA-0824-00037
Review Name: BUILDING OFFICIAL APPEAL REVIEW v.1
Review Status: Approved
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
Building Official | APPROVED | Building Official Appeal to increase travel distance to106 feet from the 100 feet maximum allowed by code is approved based upon the elevated ceiling height, occupancy load of 20 and the presence of sprinklers. | |||
Residential Building | NOT REQUIRED | ||||
Bldg Permits - Post Review | REVIEW COMPLETED | ||||
Commercial Building | REVIEW COMPLETED | The following is the result of research conducted by Mark Masek for Juan Garcia related to this appeal. Juan Garcia will be the final say in this matter. The portion of the appeal request to extend the travel distance to 106 feet, instead of the 100 feet maximum allowed by code, should be approved based upon the elevated ceiling height and the presence of sprinklers. The portion of the appeal request to not enforce the accessibility requirement of the code, and the accessible means of egress from the public way to the building’s main entry should not be approved. It could be possible to construct the accessible means of egress with a ramp or a lift as we have not heard from a Historic Reviewer regarding this proposal. The manner in which the accessibility of 31 E Toole was permitted under should not influence what is required for this project. |