Plan Number: TC-BCA-0526-00102
Parcel: 12810064D

Review Status: In Review

Review Details: BUILDING OFFICIAL APPEAL REVIEW v.1

Plan Number - TC-BCA-0526-00102
Review Name: BUILDING OFFICIAL APPEAL REVIEW v.1
Review Status: In Review
Review Date Reviewer's Name Type of Review Description Status Comments
Commercial Building Express APPROVED ACTIVITY NO. TC-BCA-0526-00102
ADDRESS/PARCEL: (349 S WILLIAMS BL TUCSON, AZ 85711)
Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed.

Should you have any questions about these Commercial Building comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976.

COMMENTS:
1. 2024 IBC 1009.4.2 Area of refuge.
a. The elevator shall be accessed from an area of refuge complying with Section 1009.6.
b. Exceptions:
i. Areas of refuge are not required at the elevator in open parking garages.
ii. Areas of refuge are not required in buildings and facilities equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2.
iii. Areas of refuge are not required at elevators not required to be located in a shaft in accordance with Section 712.
iv. Areas of refuge are not required at elevators serving smoke-protected or open-air assembly seating areas complying with Sections 1030.6.2 and 1030.6.3.
v. Areas of refuge are not required for elevators accessed from a refuge area in conjunction with a horizontal exit.
2. 2024 IBC 1009.2.2 Doors.
a. Where doors are part of an accessible route to provide access to an exit, area of refuge or exterior area of assisted rescue, maneuvering clearances shall be provided at such doors as required by ICC A117.1 in the direction of egress. Where doors lead to an area of refuge or exterior area for assisted rescue and reentry to the floor is possible, door maneuvering clearances shall be provided on both sides of the door.
b. Exception: Maneuvering clearances are not required at doors to exit stairways for levels above and below the level of exit discharge where the exit enclosure does not include an area of refuge.
1741 N 6TH AV TUCSON, AZ 85705)
3. EXCEPTION
a. With the above exception, this Appeal to the Building Official shall be approved.
4. NOTE: This appeal process will not be completed until the fee is paid.
Bldg Permits - Post Review Express PENDING ASSIGNMENT
Building Official Fast PENDING ASSIGNMENT