Plan Number: TC-BCA-0426-00092
Parcel: 11706081G

Review Status: Approved

Review Details: BUILDING OFFICIAL APPEAL REVIEW v.1

Plan Number - TC-BCA-0426-00092
Review Name: BUILDING OFFICIAL APPEAL REVIEW v.1
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
Building Official Fast APPROVED
Bldg Permits - Post Review Express REVIEW COMPLETED
Commercial Building Express REVIEW COMPLETED TC-BCA-0426-00086 410 N TOOLE AV Unit:116
Note: The following research and recommendations are provided for informational purposes only and do not constitute a final decision regarding this appeal. The final determination will be made by the Building Official.
Since the cold plunge tubs are clustered and are being installed as part of this project, a minimum of one accessible cold plunge tub is required in accordance with 2024 IBC Section 1111.4.14. This accessible unit shall be provided with an accessible means of entry complying with ICC A117.1 Section 1009.
Per ICC A117.1-2017, an accessible cold bath or spa must include an approved means of entry, such as a pool lift, transfer wall, or transfer system. Depending on the final design, compliance may be achieved through an appropriately configured transfer wall or a compliant pool lift.
As the Building Code does not provide provisions for evaluating accessibility at a programmatic level in lieu of physical access, the proposed alternative (cold rinse tub only) does not appear to meet the intent of the code. Therefore, at least one cold plunge tub within the facility is required to be accessible.