Permit Review Detail
Review Status: Requires Resubmit
Review Details: PERMANENT SIGN REVIEW v.1
Permit Number - T22OT00753
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/07/2022 | Signs | REQUIRES RESUBMIT | RE: Sign review For: Wall sign replacements AT: 3289 E Valencia / Carl’s Jr. Sign permit: T22OT00753 Reviewer: H. Thrall (HEATHER.THRALL@TUCSONAZ.GOV) Date: 11/07/22 Codes: Unified Development Code (UDC) 7A Sign Standards, National Electrical Code (NEC), Tucson – Pima County Outdoor Lighting Code (OLC) and International Building Code (IBC) 2018 Please be assured that the total sign area proposed for the location is well within code. The following review comments are for the proper permit record and for the inspections process. 1. General a. Update the permit application with the correct city business license number for Allen Industries. (Separate number than the Contractor’s number. If you need assistance, call 520-791-4566.) 2. UDC 7A:10.2. General Business / Sign area by street front / building fronts (for measuring sign area allowances) a. Please provide the lot line frontage long Hemisphere Lp at 270 feet b. Please provide the note that the dimension from the south drive thru lane north building wall is 105 (Hemisphere Lp frontage) c. Please provide a note that the dimension from the drive thru lane at the east side of the building area to the west is 83 feet (is the area facing Valencia) d. Please provide the lot line frontage along Valencia Rd as 140 feet 3. NEC / OLC: (several of these notes are for inspections purposes) a. For each sign A- D, label as such on the plans to coordinate with the application b. For signs A-D list the volts, amps, and number of circuits c. For each sign A- C, list a note that states a lock out to be provided at disconnect switch d. Provide note that “all signs to shut off at midnight or business closure if later” (i.e they may have a drive thru that operates later) e. Add note how power supply mounted to wall f. Add note for location of breaker panel (i.e. is it in kitchen / riser room, etc.) g. Add note for location of timer (i.e. next to breaker panel) h. Add note that all sign circuits shall be labeled 4. IBC: a. Add note with information on how power supply attached / typical number size of attachments for all wall signs b. Thank you for 115 mph engineered plans for drive up station c. Add electrical data for sign E – drive up station d. Note that no work to be done this permit for any menu boards e. Add note that awning in drive thru added as part of the sign permit, to maintain 9’ clearance minimum. Sending contractor’s representative a copy of the marked plans with this set of review comments. UPLOAD PLAN REVISIONS ON YOUR CUSTOMER SERVICE PORTAL, UNDER THE PERMIT NUMBER T22OT00753 |