Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T22CM08172
Parcel: 11508090A

Address:
1150 N 7TH AV

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - T22CM08172
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/03/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
02/03/2023 External Reviewers - Pima County Addressing REQUIRES RESUBMIT Please contact Pima County Addressing regarding bldg # Phone #:520-724-9512 Email: addressing@pima.gov. The address is stand alone and does not have valid building numbers.
01/27/2023 External Reviewers - SAFEBuilt REQUIRES RESUBMIT Activity Number: T22CM08172

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


STRUCTURAL REVIEW COMMENTS:
Denied
THE RESPONSE TO THE FOLLOWING COMMENTS SAYS THAT SEE SUPPLEMENTAL CALCULATIONS. NO SUPPLEMENTAL CALCULATIONS SUBMITTED TO THIS SUBMITTAL. SUBMIT SEALED AND SIGNED SUPPLEMENTAL CALCULATIONS FOR REVIEW.
1. Refer to Mechanical Drawings M104 and M105. Multiple Condenser Units (CU’s) are being added at the existing roof.
Verify the adequacy of the existing roof to support the additional loadings and submit Structural Calculations justifying that.
2. All Calculations shall be sealed and signed by Professional Engineer registered with State of Arizona per Section 107.1 of International Building Code 2018.


BUILDING REVIEW COMMENTS:
Denied
The following are comments from the initial review cycle that were not addressed as required:
1. General: Provide the complete most recently published listed through penetration and membrane penetration fire stopping assemblies. (2018 IBC Sec. 714.4.1.2, 714.4.2, 714.5.1.2, 714.5.2 & 714.6)
Clarification (Jan. 12, 2023): The intent of this comment was for the listed through penetration firestopping assemblies to be included within the plan set. The principle registered design professional indicated that the contractor is to provide this information; however, when and where this will be provided by the contractor is not clear.
Please REVISE the plan set to include these through penetration firestopping assemblies. This may not be a deferred submittal OR be provided by the contractor to the Building Inspector for field verification.
1. General: Provide listed fire-resistance joint assemblies per 2018 IBC Sec. 708.8, 715.1 & 715.3.
NOTE: For guidance, please review the UL General Information for Joint Systems (httpe://iq.ulprospector.com/en/pofile?e=212154).
Clarification (Jan. 12, 2023): See comment to above revision item.
Please revise the plan set to include these listed assemblies.


MECHANICAL REVIEW COMMENTS:
Conditionally Approved
1. Kitchen exhaust shall terminate to the outdoors in all units sheet m103(IMC2018,403.3) Complied
2. Provide a smoke damper where duct penetrates the corridor enclosure on all floors sheet M103 (IMC208,607.5.4) Complied
3. Provide a permanent means of access to roof (IMC2018,306.5) sheet M104 Complied


ELECTRICAL REVIEW COMMENTS
Conditionally Approved
E102 LEVEL 1 POWER PLAN: Could not locate Key Notes 2 & 3.
E103 LEVEL 2 POWER PLAN: Could not locate Key Note 2
E104 LEVEL 3 POWER PLAN: Could not locate Key Note 2


PLUMBING REVIEW COMMENTS:
Denied
Second Plumbing Review:
1).OK
2). OK
3). Now that the GPM load notation next to each set of roof drain conductors on plan page P103 has been added why is the roof drain load GPM for the center roof drains a higher GPM (77) with the same square footage as the other 2 areas that show 70 GPM?. -IPC 1106.2
4). SAME-P101 shows a new 4" sewer that is not connecting to existing, states see civil for continuation. Please provide Civil utility piping plan -IPC 106.3.1
5). OK


If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov
01/24/2023 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T22CM08172, T22CM08173 – DP22-290
110 E Helen St, Bldg 1 – O-3
Multi-Family (2nd Review)

TRANSMITTAL: January 24, 2023
COMMENT: Resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in O-3 Zone (UDC 4.7.15). Multi-Family is a permitted use (UDC Table 4.8-2).

1. Zoning has reviewed the building plans for compliance with DP22-0290 and all though it appears that the building plans match the DP in regard to building size and height, until the DP is approved by all review agencies Zoning cannot approve.

If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov
01/24/2023 Fire New Construction REVIEW COMPLETED
01/06/2023 PDSD Application Completeness REVIEW COMPLETED