Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - T22CM08146
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/31/2022 | NPPO | APPROVED | |||
| 10/31/2022 | Site Engineering | NOT REQUIRED | |||
| 11/14/2022 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/14/2022 | Residential Building | REQUIRES RESUBMIT | T22CM08146 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans. Each dwelling unit with kitchen requires a separate Pima County assigned street address, R319. Notate each dwelling address on the site plan. ELECTRICAL PLANS: 1. Smoke alarms are required outside each separate sleeping area, R314.3.2. Show a smoke alarm in each bedroom and outside the doorway in the immediate vicinity. 2. Show the panelboard with clear working space of 30” wide x 36” deep, E3405.2. 3. Panelboards and overcurrent protection devices may not be in clothes closets, E3405.5. Please contact the plans reviewer if you have any questions: Ken Van Karsen (520) 837-4912 PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/pdsd |
||
| 10/31/2022 | Site Zoning | REQUIRES RESUBMIT | Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Provide a floor plan of the existing single-family residence. Per UDC Section 4.9.7.B.7, for any new single-family dwelling in the R-1 zone with five bedrooms, three parking spaces are required. For every bedroom over five, one addition space is required for each bedroom. For all single-family dwellings in the R-1 zone with five or more bedrooms, and for all lots containing two or more single-family dwellings, with the second dwelling having more than one bedroom, all parking spaces must be located on-site, either in a side or rear perimeter yard. Parking spaces may not be located in a vehicular use area in any front street perimeter yard. A parking area is not required to be developed to a commercial standard. A dustproof parking surface is required to at least a minimum of two inches of compacted pea gravel. An existing covered residential parking area may be used. For reference, per UDC 11.4.3, a bedroom may be defined as: 1) any room that is designated as a bedroom; 2) Any enclosed room that has a minimum area of 60 square feet and has an accessible opening to the exterior off the building in compliance with the International Building Code (IBC), whether termed a studio, family room, study, den, bonus room, or any other name, except for a living room, dining room, kitchen, and bathrooms; and 3) Any room designated as a bedroom for the purpose of any other code requirement. 2. Clarify whether the existing guest house with unpermitted work is a sleeping quarters or accessory dwelling unit (ADU). Review UDC 6.6.3.A and .B for the definitions of sleeping quarters and ADU. Further Zoning comments may be forthcoming depending on the use of the guest house. 3. Provide a setback dimension between the east lot line and the open structure near the southeast corner of the dwelling. Aerial imagery and Google Street View show an expansion of this structure and a near zero setback. A Design Development Option or a Board of Adjustment variance may apply. If you have any questions about this transmittal, please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |