Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - T22CM08008
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/31/2022 | Fire New Construction | APPROVED | |||
| 11/02/2022 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/02/2022 | External Reviewers - Willdan | REQUIRES RESUBMIT | Activity Number: T22CM08008 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. DENIED: Please list Special Inspections required and complete/submit SIC form as needed 2018 IBC chpt 17 & 107.2.1. Provide code data and legible site plan as well as shade cover elevations/drawings. 2018 IBC 107.2.1 Provide shade cover material, mfr cut sheet, flame spread/smoke index etc. 2018 IBC Sec 803 Provide Setback distance from nearest building. (note-difficult to verify as Site plan is not legible) Is shade cover at an entrance to a building, being used as carport, etc.-more info please. 2018 IBC 107.2.1 If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
||
| 10/31/2022 | Site Engineering | REQUIRES RESUBMIT | Include a site plan and show where structural supports will be located in relationship to the building and to parking spots. Lianne Evans lianne.evans@tucsonaz.gov 520-837-5341 |
||
| 11/01/2022 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T22CM08008 7444 E Broadway Blvd – C-1 Shade Structure (1st Review) TRANSMITTAL: October 27, 2022 This site is located in C-1 Zone (UDC 4.7.20). 1. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. The DP is a separate submittal from the building plans and is submitted at: https://docs.tucsonaz.gov/Forms/tucsonpermitapp, using Submission Type “Site Review”. As DP21-0075 is still open and has not been finaled Zoning recommends that a revision to the existing DP be submitted and approved. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |