Review Date Reviewer's Name Type of Review Description Status Comments
11/22/2022 Site Engineering NOT REQUIRED
12/02/2022 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/01/2022 External Reviewers - Willdan REQUIRES RESUBMIT Activity Number: T22CM07811

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


DENIED:
SPECIFYTYPE OF EGRESS WINDOW FOR VERIFICATION OF MINIMUM OPENING AREAS. IBC 1030.2
SPECIFY THE OCCUPANT LOAD OF THE RESIDENTIAL GROUP HOUSE. IBC 1004.1
CARBON MONOXIDE DETECTION ALARMS ARE REQUIRED IN GROUP R
OCCUPANCIES CONTAINING A FUEL BURNING APPLIANCE. IBC 915.1
CARBON MONOXIDE DETECTION ALARMS SHALL BE INSTALLED OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITYOF THE BEDROOMS. IBC 915.2.1
CARBON MONOXIDE ALARMS SHALL RECIEVE PRIMARYPOWER SOURCE FROM THE BUILDING WIRING. A BATTERYBACK UP IS REQUIRED. IBC 915.4.1
WHERE A CARE FACILITYIS PART OF A DWELLING, ONLYTHE PORTION OF OF THE STRUCTURE UTILIZED BYTHE CARE FACILITYIS REQUIRED TO BE ACCESSIBLE. IBC 1103.2.12


If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov
12/02/2022 Fire New Construction REQUIRES RESUBMIT
10/31/2022 Site Zoning REQUIRES RESUBMIT FROM: Samuel Rogers
PDSD Zoning Review Section

PROJECT: T22CM07811 (Project Number)
Behavioral Health Adult Service Care (1st Review)
7325 e Fayette St. R-1

TRANSMITTAL DATE: 10-31/2022

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.


01. COMMENT: Remove the references to “group home” from your plans, a group home is not an allowed use in this zone.


02. COMMENT: The plan set indicates that the proposed use is “Behavioral Health Adult Services Care”, this is not a use classification, but is a mix of two uses. Adult Care Service is not an allowed use in the R-1 zone but Physical and Behavioral Health Service is an allowed use. Clarify the proposed use on the next submittal. See use definitions below:

1. Adult Care Service
A Residential Care Service providing lodging, meals , supervision, and other support services to elderly or physically disabled individuals not related to the owner/manager of the facility. Typical uses include adult care homes, adult care facilities, and supervisory care facilities.

2. Physical and Behavioral Health Service
A Residential Care Service providing lodging, meals , treatment, counseling, and supervision to persons with behavioral disorders or developmental disabilities or to physically disabled individuals not related to the owner/manager of the facility. Typical uses include group homes for the developmentally disabled, group homes for the seriously mentally ill , specialized treatment homes, group foster homes, and recovery homes for substance abusers. This category does not include facilities used for penal or correctional purposes or for adjudicated delinquents other than status offenders .



If you have any questions about this transmittal, Contact Samuel Rogers at Samuel.Rogers@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans