Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T22CM07802
Parcel: 123080900

Address:
2516 E MABEL ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - T22CM07802
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/21/2022 NPPO APPROVED
12/01/2022 Historic NOT REQUIRED Property is located within Blenman-Elm National Register Historic District and it is not within a Historic Preservation Zone (HPZ). No review by COT HPO. It is recommended that the applicant confer with the State Historic Preservation Office (SHPO) to ensure that the proposed work is consistent with the Secretary of the Interior's Standards and the property can be maintained as a contributing resource. The SHPO can be contacted at (602) 542-6943.
01/18/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/31/2022 Residential Building REQUIRES RESUBMIT T22CM07802

PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. Place the code reference on the plans.

Provide a clear and concise construction plan set. Sample plans are available at https://www.tucsonaz.gov/pdsd/residential-permits

SITE PLAN:

Provide a site plan showing all buildings, R106.1.1. Show the location of utility lines to the building.

STRUCTURAL PLAN:

Show the beam on top of post with appropriate post top hardware for supporting live and dead structural loads. Show a correction or provide an engineer’s calculation, design and seal for a performance solution when proposed design (angle bracket) is not code compliant with the IRC, R301.1.

SECTIONS - DETAILS:

Show the ledger with stucco removal between wall studs and ledger.


If you have any questions, please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review

PLEASE NOTE: Planning and Development Services launched Tucson Development Center Online on Monday, October 31. TDC Online is a self-service portal that will provide transparency throughout the permitting process. To sign up for an account and submit an application, visit https://tdc-online.tucsonaz.gov
10/31/2022 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T22CM07802
2516 E Mabel St – R-1
Porch Addition (1st Review)

TRANSMITTAL DATE: October 24, 2022

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R Specific Standards 4.9-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use.7.B.5 – 9.

1. The lot coverage calculation is not correct and shall include all vehicle use areas whether improved or unimproved, see UDC Article 6.4.3 and the lot coverage calculation example shown on the Residential Plot Plan Requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf.

2. The property dimensions provided on the plan are not correct. Review the Assessor’s Record Map and provide the correct dimensions.

3. Provide a legal description, “LENMAN W30' LOT 4 & E30' LOT 5 BLK 7” on the plot plan.

4. Provide the zoning of this parcel and all adjacent parcels on the plot plan.

5. Based on current aerial photos there is a shade structure added to the east side of the detached garage some time after 2014. Zoning was not able to fine approved permit documents for this structure. Either provide approved permit documents for this structure with your next submittal or include it in this permit.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov
01/18/2023 Site Engineering REVIEW COMPLETED