10/29/2022 Site Engineering APPROVED
10/29/2022 Site Landscape APPROVED
10/31/2022 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/31/2022 Residential Building REQUIRES RESUBMIT T22CM07686
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans.

A living space with cooking features is an independently functioning dwelling and requires compliance with the 2018 IRC and City of Tucson building ordinances for Family Dwelling requirements.

Each dwelling unit with kitchen requires a separate Pima County assigned street address, R319. Notate each dwelling address on the site plan.

GENERAL COMMENTS :

1. Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson Ordinance #10463 on 10/16/2007. Remove the Santa Cruz County reference on sheet #1.
2. All SFR and Duplex plans submitted after July 1, 2009, require a solar photo-voltaic system, or future installation preparation City of Tucson Ordinance #10549 .
a. Show a minimum 300 SF clear solar-ready zone on a roof or framing plan, T103.3. Model plans should show four typical south facing roof surfaces.
b. Label a double breaker space for future Photo Voltaic on the panel schedule opposite end from the main/supply side, T103.9. Breaker space location is correct.

SITE PLAN:

1. Show a street address for each dwelling on the site plan, R319.

PLANS:

1. Show a maximum ½” floor elevation changes at a notated accessible route entrance on the floor plan, R106.1.1. Include the threshold condition at the vehicle doorway or an exterior hinged door when the garage is used for the accessible route.

SECTIONS - DETAILS:

1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. Update roof/ceiling insulation details on sheet #6.

MECHANICAL PLANS:

1. Provide (an HVAC system with fresh air intake) whole-house mechanical ventilation, or controlled exhaust with a calculated airflow rate, R303.4; N1103.6 & M1505.4. Show the system and appropriate flow rate setting on the plans. A four bedroom dwelling of 1501 – 3000 SF requires a 75 CFM continuous setting.

ELECTRICAL PLANS:

1. Show the Garage Receptacle Circuit as 20 AMP rather than 15 AMP, E3901.9. Update circuit #26 wire and breaker size.
2. Show or notate a disconnect means or a locking breaker for the water heater, E4101.5. Also, show a water heater circuit on the panel schedule.
3. Specify high-efficacy lamps for at least 90% of all lighting fixtures, N1104.1. Update note #24.
4. Include the Electric Vehicle load entry (typically 7680 watts) in the electrical load calculations (continuous demand) like the HVAC entry, N1104.2.2. The PV load entry may be removed from the calculation.

INTERNATIONAL ENERGY CONSERVATION CODE:

1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans.

Please contact the plans reviewer if you have any questions:
Ken Van Karsen
(520) 837-4912 PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

PLEASE NOTE: Planning and Development Services launched Tucson Development Center Online on Monday, October 31. TDC Online is a self-service portal that will provide transparency throughout the permitting process. To sign up for an account and submit an application, visit https://tdc-online.tucsonaz.gov
10/29/2022 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T22CM07686
4108 S 14th Ave - R-2
New SFR (1st Review)

TRANSMITTAL: October 19, 2022
Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal.

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10.

1. Based on aerial photos there is a shed located in the northwest corner of the site that is not shown on this plan. This shed shows up some time after 2012 and Zoning was not able to find a permit or zoning compliance for this structure. Show this structure on the plans along with setback dimensions and include it in the lot coverage calculation. It does not appear that this structure meets the minimum perimeter yard setback of 6’-0” and may require neighbors setback waivers. To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s):
My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________

2. Provide a dimension from the center line of 14th to the face of curb and from face of curb to the east property line.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.