Review Date Reviewer's Name Type of Review Description Status Comments
11/29/2022 Fire New Construction APPROVED
11/02/2022 Site Engineering NOT REQUIRED
11/29/2022 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/02/2022 External Reviewers - Willdan REQUIRES RESUBMIT Activity Number: T22CM07635

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


DENIED:
Show Accessible path of Travel from Bistro to new seating area.
Show elevations. Will this be level with existing sidewalk? If not show step or slope entry to seating area.
Provide seating layout. Provide accessible seating based on the number of seats provided
Provide additional rail within 6 inches from the decking to protect wheel chairs from going off ledge.
Provide Details of ADA Access.


If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov
11/01/2022 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T22CM07635
63 E Congress St – OCR-2
Steaterie Addition – (1st Review)

TRANSMITTAL: October 25, 2022

This site is located in OCR-2 Zone (UDC Article 4.7.27). Food Service is a permitted use in the zone (UDC Table 4.8-4)

1. The proposed Steaterie requires a new development package. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements the checklist for Minor Development Changes to Existing Commercial/Industrial Sire, found at: https://www.tucsonaz.gov/files/pdsd/forms/Minor_Changes_to_Commercial_Industrial_Sites_.pdf, must be submitted and approved prior to approval of this building plan. The DP is a separate submittal from the building plans and is submitted at: https://docs.tucsonaz.gov/Forms/tucsonpermitapp, using Submission Type “Site Review”.

2. As the proposed seating area is located within a COT right-of-way approval by COT DTM will be required.

3. As this site is located within the COT Downtown core review by Historic and Rio Nuevo Area (RNA) will be required.

If you have any questions about this transmittal, please contact Nicholas Ross at Nicholas.Ross@tucsonaz.gov.