Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.3
Permit Number - T22CM07618
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/05/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/05/2023 | Residential Building | REQUIRES RESUBMIT | SITE PLAN: Provide a site plan showing dimensions of all buildings requiring a permit, R106.1.1. Show the location of all utility lines from property line to building(s) along with required alterations. ELECTRICAL PLANS: 1. Provide a Riser Diagram showing a sub panel and feeder size and location, NEC 225.30, E3403, Table E3704.2(1). 2. Designate the circuit number at the location of each light fixture, receptacle, appliance, and equipment disconnect switch, E3404.12. 3. Provide a panel schedule showing panel size, circuit numbers, ampacity, wire size and general description, E3404.13 & E3706.2. |
||
| 06/28/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: T22CM07618 Garage 8499 E WOODLAND RD Zoning SR TRANSMITTAL DATE: June 28, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. As no site plan was submitted these comments are still applicable. 1.COMMENT: Provide a Residential Plot Plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf This shall in include: These comment are still applicable, provided below is the Pima County assessors Record Map : https://www.asr.pima.gov/ParcelData/Map/Arm/MP09/09021_01.pdf b. Zoning of adjacent parcels c. Property line distances This comment is still applicable: Since the gross floor area proposed for the new metal building will exceed the 50% limitation rule zoning is unable to approve the plan set. A couple of options would be to attach the metal building to the existing dwelling or to request a variance for the gross floor area limitation. 2.COMMENT: Provide the gross floor area of the Est. House and the other detached accessory structures on the plan, Per UDC Article 6.6.3.E “The total gross floor area (gfa) of all accessory structures shall not exceed 50% of the gfa of the principal structure . Accessory structures less than 200 square feet gfa and accessory dwelling units are exempt from this requirement” 3. COMMENT: This comment is still applicable: Per UDC Article 6.6.3.D. “Accessory structures , except for accessory dwelling units , shall not exceed 12 feet in height, unless attached to a principal structure . If attached to the principal structure , maximum height permitted shall be the same as for the principal structure” a Board of Adjustment for Variance is required. Board of Adjustment requirements and application can be found at: https://www.tucsonaz.gov/files/pdsd/codes/Zoning_Administration_Application_BA_fillable.pdfIf you have any questions about the Board of Adjustment contact: Wyatt Berger at wyatt.berger@tucsonaz.gov or Georgia Pennington at georgia.pennington@tucsonaz.gov. If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
| 06/29/2023 | Zoning Modifications - Variance | REQUIRES RESUBMIT | Variance case C10-23-07 is currently scheduled to be heard by the Board of Adjustment July 26, 2023. | ||
| 06/23/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |