| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/28/2022 | Site Engineering | APPROVED | |||
| 10/28/2022 | Site Landscape | APPROVED | |||
| 11/09/2022 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/28/2022 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: T22CM07594 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1. Provide a foundation and a structural framing plan for the new work. Include all framing sizes, beams, fasteners, reinforcing and any additional information required to build a complete addition. Include how the new structure will tie into the existing. 2. Indicate the live and dead loads for the new structure as well as the designed wind and seismic category. The minimum designed wind speed is to be 115 mph per 3 second gust and the seismic category is B. Revise drawings if needed for new criteria. 3. Provide a braced wall line layout showing the location of braced wall panels and fasteners in accordance with the 2018 IRC R602.10. BUILDING REVIEW COMMENTS: Denied 1. The plans do not include all information required to do a full review on this project. Additional comments may be required once all information is received. 2. Provide details on the new stair to the existing workshop including the overall clear width of the stair, the size of the treads and risers, and the required handrail details. 3. Indicate on the drawings that fireblocking will be installed to cut off both vertical and horizontal concealed draft openings between stories and attic or roof area. 2018 IRC R302.11. 4. Indicate that the soil under the slab and around the footings will be treated for termites prior to the pouring of the concrete. 2018 IRC R318. 5. Indicate a minimum of 6” foundation height above finished grade will be provided and that the grade will be sloped to drain water away from the foundation., R404.1.6. MECHANICAL REVIEW COMMENTS: Conditionally Approved No mechanical work has been included in this submittal ELECTRICAL REVIEW COMMENTS Denied 1. Provide an electrical layout for the new addition. Include all receptacles, lights and switches. 2. Provide a panel schedule for the structure that indicates the new circuits and the size of the exiting electrical service include any sub panels PLUMBING REVIEW COMMENTS: Conditionally Approved No plumbing work has been included in this submittal If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
||
| 11/09/2022 | Fire New Construction | REQUIRES RESUBMIT | |||
| 10/28/2022 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: T22CM07594 Garage 1422 N PAINTED HILLS RD Zoning RX-2 TRANSMITTAL DATE:?October 11, 2022 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: Per Unified Development Code (UDC) TABLE 6.3-1.A: DIMENSIONAL STANDARDS FOR THE RH, SR, SH, RX-1, & RX-2 ZONES, RX-1 Zone the required perimeter yard setback from the proposed addition to the north property line is 20’-0”, proposed perimeter yard setback is 5’-0”. A Design Development Option (DDO) will need to be processed and approved to reduce the setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov. If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |