Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - T22CM07520
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
03/14/2023 | NPPO | APPROVED | |||
03/20/2023 | Site Engineering | APPROVED | |||
04/04/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
04/03/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: T22CM07520 4433 E Seneca St. Zoning - R-2 New SFR (1st Review TRANSMITTAL DATE: April 3, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. COMMENT: Provide a Residential Plot Plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf This shall in include: a. This comment was not addressed. Zoning of adjacent parcels. b. This comment was not addressed. Property line distances. 2. COMMENT: The street perimeter yard setback shown from the garage to the south property line on the plan is not correct. Per UDC Article 6.4.5.C.1.a within established areas, the minimum required front street perimeter yard is 20 feet or one and one-half the height of the proposed wall (H), measured from the street line, whichever is greater, up to a maximum of 90 feet. Provide setback dimension from the southwest corner of the garage to the southwest property line. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. As fully dimensions were not provided on the model plan Zoning cannot verify front street perimeter yard setback requirements. If the wall height from design grade the where the wall meets the eave at its highest point is less than 13’-4” the required street perimeter yard setback is 20’-0”. If the distance from the southwest corner of the garage to the southwest property line a Design Development Option (DDO) with be required. 3. COMMENT: The street perimeter yard setback shown from the SFR to the west property line on the plan is not correct. Per UDC Article 6.4.5.C.1.b Where a lot abuts more than one street, the owner chooses which street lot line is the front lot line. As the actual setback dimension was not provided Zoning cannot verify if the SFR meets the required 10’-0” side street perimeter yard setback. If the side street perimeter yard is less ten feet a DDO must be submitted and approved to reduce the side street perimeter yard setback. 4. COMMENT: Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. As height dimensions were not provided on T19-M0106 elevations from design grade to the highest point of the wall to where the wall meets the eave, Zoning cannot verify the perimeter yard setback dimensions for the north and east property lines. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
03/13/2023 | PDSD Application Completeness | REVIEW COMPLETED | |||
04/04/2023 | Residential Building | REVIEW COMPLETED |