Permit Number: T22CM07088
Parcel: 12912177A

Address:
1102 E 30TH ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - T22CM07088
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/02/2022 NPPO APPROVED
12/15/2022 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/15/2022 Residential Building REQUIRES RESUBMIT T22CM07088 R1
PLAN REVIEW COMMENTS
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide an updated complete plan set with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:
The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.
GENERAL REQUIREMENTS:
1. The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans.
2. Consolidate pages of construction plans into a single .PDF file as prescribed at the PDSD web site.
3. Provide a clear and concise construction plan set. Sample plans are available at https://www.tucsonaz.gov/pdsd/residential-permits
SITE PLAN:
1. Show the location of utility lines on the property, R106.1.1. Identify the utility lines requiring upgrade or replacement (i.e., Overhead Electrical Line).
FOUNDATION PLAN:
1. Dimension the footing length, width, and depth into undisturbed soil for each footing type and condition, R403.1. Show the minimum 12” reinforced footing depth below the undisturbed ground surface (below the 4” concrete slab), R403.1.

SECTIONS - DETAILS:
1. Provide a complete roof framing plan with beams and rafters sized with appropriate prescriptive load carrying capacity, R301.1 or provide an engineer’s sealed plan set for performance compliance consideration, R301.1.3.
2. Show the size of each fastener including the clips and roof screws.

Please contact the plans reviewer if you have any questions:
Ken Van Karsen
520 837-4912
City of Tucson Residential Plan Review
12/06/2022 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL
FROM: PDSD Zoning Review


PROJECT:
T22CM07088
1102 E 30th St - R-2
Detached shade structure (2nd Review)

TRANSMITTAL: December 6, 2022
Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal.

Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A.
This comment is still applicable

1. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Perimeter Yard setbacks for a structure such as the one proposed are measured from the post supporting the roof. As setback dimensions were not provided Zoning can not provide comment on the proposed setbacks. within a perimeter yard and is detached from a principal structure shall comply with the perimeter yard width standards of the principal structure, except that the accessory structure may be built to a parcel line with the consent of the adjoining or, when separated by an alley, adjacent property owner(s). To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s):
My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________

Provide the setback dimension for the new porch addition to the south. If you are not able to obtain a neighbor setback waiver a DDO may be required.


2. Provide the height and setback information for the structure to the west.


If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov
12/02/2022 PDSD Application Completeness Express REVIEW COMPLETED
12/02/2022 Site Engineering REVIEW COMPLETED