Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T22CM07001
Parcel: 140550510

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - T22CM07001
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/28/2022 Site Engineering APPROVED
11/28/2022 Site Landscape APPROVED
11/29/2022 Site Zoning APPROVED
11/29/2022 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/28/2022 Residential Building REQUIRES RESUBMIT 12. Roof projections extending into the 3-foot fire separation distance to the neighboring property line require not less than one-hour fire-resistive construction on the underside, R302.1 (City of Tucson Amended). The fire protected overhang may not extend closer than 24” from the property line.
13. A roof overhang may not extend closer than 24” to the neighboring property line. Any part of a roof projection extending into the 3-foot fire separation distance from the property line requires not less than one-hour fire-resistive construction on the underside, R302.1 (City of Tucson Amended).
11/28/2022 PDSD Application Completeness Express REVIEW COMPLETED