| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/28/2022 | Residential Building | APPROVED | |||
| 11/28/2022 | Site Engineering | APPROVED | |||
| 11/28/2022 | Site Landscape | APPROVED | |||
| 11/28/2022 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/28/2022 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T22CM06999 5727 E Camino Del Apadrinar - R-1 RCP New SFR (2nd Review) TRANSMITTAL: November 28, 2022 This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. 1. This comment was not addressed. Nowhere on the approved tentative plat does it show a 20’ street setback. The front street perimeter yard setback is not correct and for the main dwelling should be listed as 21’ or the height of the H = The height of the proposed exterior building wall, greater of the two as measured from the from the outside edge of the nearest adjacent travel lane, UDC Article 6.4.5.C.2 and Table 6.4.5.C-1. The street perimeter yard setback to the garage should be listed as A minimum setback of 19 feet from the back of sidewalk UDC Article 6.4.5.C.2.b.(1). 2. This comment was not addressed. The side street perimeter yard setback is not correct and for the main dwelling should be listed as 21’ or the height of the H = The height of the proposed exterior building wall, greater of the two as measured from the from the outside edge of the nearest adjacent travel lane, UDC Article 6.4.5.C.2 and Table 6.4.5.C-1. For this site the setback is measured from back of wedge curb as no parking is allowed along the east side of Avenda Santa Carina. 3. This comment was not addressed. Provide a setback dimension from the proposed SFR to the north property line. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 11/28/2022 | PDSD Application Completeness Express | REVIEW COMPLETED |