Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - T22CM06474
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
12/14/2023 | Site Engineering | APPROVED | |||
11/16/2023 | Site Zoning | APPROVED | |||
12/14/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
11/15/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Madeline Nelson mnelson@safebuilt.com Denied Reason: Date Completed : 11/15/2023 1:40:00 PM 1. S101/S102 - CONFLICTING INFORMATION: Revisions to the latest Foundation Plan S101 removed a east-west oriented masonry wall located at approximately Grid 4.8/H thru M. However, the latest Framing Plan S102 still shows a wall at this location, supporting existing steel beams. Please confirm if this wall is being demolished and how the existing floor members are being supported. 2. S101 - MISSING DETAILS: Revisions to the latest Foundation Plan S101 include addition of new section cuts for Details 130, 131, 132, 133, 134. Detail Sheet S302 was not resubmitted with this round of revisions and does not include any of these details. Please provide Details 130 thru 134 for review. 3. S102 - MISSING DETAILS: Revisions to the latest Framing Plan S102 include addition of new section cuts for Detail 239 and plan notes referencing Details 237 and 238. Detail Sheet S402 was not resubmitted with this round of revisions and does not include these details. Please provide Details 237 thru 239 for review. Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 11/15/2023 12:47:12 PM Mechanical N/A Electrical(E) Reviewer Yhulmer Izquierdo yizquierdo@safebuilt.com Approved Reason: Date Completed : 11/8/2023 6:43:23 PM Plumbing N/A |
||
11/22/2023 | Fire New Construction | REVIEW COMPLETED | |||
11/08/2023 | PDSD Application Completeness | REVIEW COMPLETED |