Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - T22CM06114
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/27/2022 | Commercial Plumbing | APPROVED | |||
10/27/2022 | Fire New Construction | APPROVED | |||
11/22/2022 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
11/22/2022 | External Reviewers - Willdan | REQUIRES RESUBMIT | Activity Number: T22CM06114 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. Denied 1. A0.02 A117 fig 604.4 Please add vertical grab bar to accessible toilets. 2. 107,1301 Please submit comcheck energy code analysis or equivalent for the project. 3. Roof drains 1502.2 Please recheck overflow drains and scuppers are provide. 4. 107,1603 GSN Please add material or minimum grade requirements for the shipping containers for the project. Include minimum structural properties required by your calculations to satisfy code design forces. 5. 1704 GSN Please list all special inspection items for the project. Note whether the inspections are continuous or periodic. 6. 1704 Please submit completed geotechnical and structural special inspection forms for the project. A0.01 There are 3 mechanical drawings in the set. A0.01 List all deferred submittals. A1.04 Provide of roof drainage calculations IPC 1101.7 These doors shall be insulated M1.0 Provide outside air into restrooms and janitors utility Show flues through the roof M3.1? M3.0? Provide pounds of refrigerant in the total system. Provide refrigerant volume (include the piping volume) in the smallest space for a rupture or full loss of refrigerant charge in accordance IMC 1104.4.1 Non-communicating Spaces. In the kitchen hood schedule Piping? E1.01 Provide photometric grid and footcandle values. Comply with Tucson/Pima CountyOutdoor Lighting Code E1.01 Provide a home run for this circuit E1.01 Provide exit signs There is no unit here DCU-3 MCA If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
||
10/27/2022 | Site Engineering | REQUIRES RESUBMIT | {Activity date: 09/08/2022; Status: Reqs Change; Reviewer: SBLOOD1; Title: 3RD PARTY REVIEW - COMMERCIAL; Comment: The DP needs to be approved before the building plans can be approved.Stephen Blood(520) 837-4958Stephen.blood@tucsonaz.gov} | ||
10/27/2022 | Site Zoning | REQUIRES RESUBMIT | {Activity date: 08/23/2022; Status: Reqs Change; Reviewer: SSHIELD1; Title: 3RD PARTY REVIEW - COMMERCIAL; Comment: ZONING REVIEW TRANSMITTALFROM: PDSD Zoning ReviewPROJECT: T22CM06114 – DP21-02383050 E Fort Lowell Rd – C-1New Food Service – (1st Review)TRANSMITTAL: August 23, 2022This site is located in C-1 Zone (UDC Article 4.7.29). Construction services is a permitted use (UDC Table 4.8-4), subject to Use Specific Standards 4.9.4.M.1 & 5 and 4.9.13.O.1.Zoning has reviewed the building plans for compliance with DP21-0238 and there is a discrepancy between the plans. Building plan sheet A1.02 shows an “OUTDOOR PATIO” along he east side of the “INDOOR PATIO”. This patio was not shown on the DP and was not accounted for in the vehicle and bicycle parking requirements. Until the plans match Zoning cannot approved the building plans.If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.} |