Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T22CM06021
Parcel: 130102250

Address:
3242 E 27TH ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.3

Permit Number - T22CM06021
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/07/2023 Zoning Modifications - DDO APPROVED
06/07/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/24/2023 Site Zoning REQUIRES RESUBMIT FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: T22CM06021
3242 E 27TH ST Zoning R-1

TRANSMITTAL DATE:‎March 2, 2023

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

1.COMMENT: The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Based on a wall height of 12’-0” the required perimeter yard setback from the proposed sleeping quarters to the east property line is 8’-0”, proposed setback is 1’-7”. At a minimum, a neighbor’s setback waiver is required to reduce the perimeter yard setback. To secure this waiver the following text shall be provided on the plot plan and be signed and dated by the owner of the property to the east:
My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________

If you are unable to secure the neighbor’s setback waiver a Design Development Option (DDO) will need to be processed and approved to reduce the setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. If you have questions about the DDO application or process please contact Georgia Pennington @ georgia.pennington@tucsonaz.gov



If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by emailPaul.Camarena@tucsonaz.gov
03/21/2023 PDSD Application Completeness Express REVIEW COMPLETED