Permit Number: T22CM05429
Parcel: 127032110

Address:
5750 E 2ND ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - T22CM05429
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/21/2022 Site Engineering APPROVED
12/15/2022 Zoning Modifications - DDO APPROVED
12/19/2022 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/16/2022 Residential Building REQUIRES RESUBMIT T22CM05429

PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. Place the code reference on the plans.

Provide a clear and concise construction plan set. Sample plans are available at https://www.tucsonaz.gov/pdsd/residential-permits

SITE PLAN:

Provide a site plan showing all utility lines, R106.1.1.

STRUCTURAL PLAN:

Show the beam and joist sizes and spacing for supporting live and dead structural loads. Show a roof framing plan or provide an engineer’s calculation, design and seal for a performance solution when proposed design is not code compliant with the IRC, R301.1.

SECTIONS - DETAILS:

Show a complete cross-section detail with foundation and fastener size and spacing for prescriptive 2018 IRC compliance, R106.1.1. Include a minimum 12” depth with #4 rebar reinforced footing, R403.1. Show all fastenings of anchor bolt embedment and H2.5 equivalent uplift. Or manufactured assembly requires submittal of a professional engineer stamped plan set. This document is available from the structure manufacturer which verifies that an Arizona Professional Engineer has reviewed the design for 2018 IBC performance compliance for wind loading with appropriate foundation fastening, R106.1.

ELECTRICAL PLANS:

Show any lighting in accordance with the City of Tucson Outdoor Lighting Code.


If you have any questions, please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/pdsd
12/19/2022 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: Wyatt Berger
Planner

PROJECT: T22CM05429
5750 E 2nd St – R-1
Iron carport (2nd Review)

TRANSMITTAL DATE: December 19, 2022

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

1. Zoning cannot approve this building permit until CE-VIO1222-00973 ("ROW/work without permit property wall") is abated and resolved.

If you have any questions about this transmittal, please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov.