Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - T22CM05272
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/08/2022 | Site Zoning | APPROVED | |||
| 12/07/2022 | NPPO | NOT REQUIRED | |||
| 12/23/2022 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/23/2022 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: T22CM05272 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: DENIED 1. Provide the designed live and dead loads for the structural design of the additions as well as a basic designed wind speed of 115 mph and a seismic category B. 2018 IRC table R301.2(1) as amended. BUILDING REVIEW COMMENTS: CONDITIONALLY APPROVED 1. The renovation of the existing porch to bedroom #5, including door 7 have been removed from the plans MECHANICAL REVIEW COMMENTS: DENIED No mechanical information has been provided with the resubmittal 1. Provide a mechanical plan for the new additions and indicate if they will be tied to an existing system that is large enough to except the new load or if new unit(s) will need to be installed. 2. Note on the drawings that all bath fans will be exhausted directly to the exterior. 2018 IRC M1505.2. ELECTRICAL REVIEW COMMENTS DENIED 1. Indicate the location of all smoke detectors in the house including the existing bedrooms. Smoke detectors shall be installed in each sleeping room, and outside of each sleeping room in the immediate vicinity of the bedroom. 2018 IRC R314.2. All smoke detectors shall receive their primary power from the building wiring with a battery backup and shall be interconnected so that the actuation of one alarm will activate all. 2018 IRC R314.4.. The detectors in the existing bedrooms may be battery only per the exception #2 R314.6. 2. Indicate the location of all carbon monoxide detectors on the plan including for the existing bedrooms. Carbon monoxide device shall receive their primary power from the building wiring with a battery backup and shall be interconnected so that the actuation of one alarm will activate all. 2018 IRC R314.4. Smoke detectors and carbon monoxide alarms may be combined. PLUMBING REVIEW COMMENTS: DENIED Comments not addressed or comments could not be located on the revised plans 1. Update plumbing plan note 13 to indicate the showerheads and faucets to not exceed 2.5 gallons a minute. Ordinance 7178. 2. Indicate if the new fixtures will be tied to an existing water heater or if a new water heater will be provided. Show the location of the water heater on the plans. 3. Indicate where the new plumbing fixtures will be tied into the existing water lines, only the sewer was shown. 4. Note on the drawings that all plumbing drain, waste and vent systems shall be tested for leaks in accordance with the 2018 IRC P2503.5 prior to concealing. 5. The plumbing plans appear to indicate a hose bib in the existing wall where the new master bedroom addition is located. Clarify it this is an existing hose bib that is being relocated to the front of the house 6. Provide a gas piping diagram for any new gas appliances on the drawing including water heaters and HVAC units or indicate no gas piping is required as part of this submittal. If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
||
| 12/02/2022 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 12/02/2022 | Site Engineering | REVIEW COMPLETED |